Sandwell HMO fire safety requirements

Sandwell publishes its own HMO fire safety standard, "Sandwell Council Standards and Amenities Guide for Houses in Multiple Occupation (HMO)" (Version 01, approved 19 June 2024). It is based on the Homestamp standard, which 10 other councils use too.

Is a fire risk assessment needed for the licence?

Yes, with your licence application

The council lists a written fire risk assessment as one of the documents you send with your HMO licence application.

Who can carry it out?

A "competent person"

The council says a "competent person" must carry it out. In fire safety law that means someone with enough training, experience or knowledge to assess the house properly. A careful landlord can meet that.

Which standard applies?

Sandwell Council Standards and Amenities Guide for Houses in Multiple Occupation (HMO)

Published Version 01, approved 19 June 2024.

Read the council's document →

When did we last check?

15 October 2026

We re-check every council's documents each month and update this page when they change.

What Sandwell expects in 3 typical HMOs

Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.

2-storey shared house, 5 tenants

Fire alarm system
Grade D2, LD3
Fire doors on bedrooms
Not required
Fire door on the kitchen
Required
Protected escape route
Not required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Not required

3-storey shared house, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Not required

3-storey bedsits with cooking in rooms, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked heat detector and a standalone smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Not required
  • Grade D2 (mains alarms with a replaceable backup battery)
  • Grade A (a panel system with call points)
  • LD3 (escape route only)
  • LD2 (escape route plus rooms where fires are likely to start)

In the council's own words

The wording these requirements come from, quoted from the published documents.

Fire alarms

Council's own standard

“2 Storey Shared • Sound traditional • Grade D LD3 ... Kitchen door to be FD30s ... All other doors to be sound,”
Sandwell Council Standards and Amenities Guide for Houses in Multiple Occupation (HMO), Version 01, approved 19 June 2024

Fire doors

Council's own standard

“2 Storey Shared • Sound traditional • Grade D LD3 ... Kitchen door to be FD30s ... All other doors to be sound,”
Sandwell Council Standards and Amenities Guide for Houses in Multiple Occupation (HMO), Version 01, approved 19 June 2024

Escape route

Council's own standard

“2 Storey Shared • Sound traditional • Grade D LD3 ... Kitchen door to be FD30s ... All other doors to be sound,”
Sandwell Council Standards and Amenities Guide for Houses in Multiple Occupation (HMO), Version 01, approved 19 June 2024

Kitchen heat detector

LACORS national guide

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Emergency lighting

Shared regional standard

“Subject to a fire risk assessment emergency lighting should not be necessary, provided that the escape route is not long or complex and there is effective artificial or borrowed lighting. ... Where emergency lighting is considered to be necessary, it should be provided in accordance with the current BS 5266 Part 1 (or equivalent) to cover the protected escape route.”
A Guide to Fire and Security Protection in Multi-Occupied Residential Properties (Homestamp Consortium), Revision 2015

Fire extinguishers

Shared regional standard

“Landlords should consider the following points where extinguishers are to be provided ... devices. Unless a fire is very small, it is best ... on balance to encourage people simply to”
A Guide to Fire and Security Protection in Multi-Occupied Residential Properties (Homestamp Consortium), Revision 2015

Spotted something out of date? Tell us and we will check it.

Common questions

Do I need a fire risk assessment for a Sandwell HMO licence?
The council lists a written fire risk assessment as one of the documents you send with your HMO licence application.
Can I do my own HMO fire risk assessment in Sandwell?
The council says a "competent person" must carry it out. In fire safety law that means someone with enough training, experience or knowledge to assess the house properly. A careful landlord can meet that.
Which fire safety standard does Sandwell use for HMOs?
Sandwell publishes "Sandwell Council Standards and Amenities Guide for Houses in Multiple Occupation (HMO)" (Version 01, approved 19 June 2024).
What fire alarm does a 3-storey shared house need in Sandwell?
For a typical 3-storey shared house with 6 tenants, Sandwell's rules work out at Grade A, LD2, plus a linked smoke alarm in each letting. Your house may need something different depending on its layout, so check it properly with a fire risk assessment.