Bromsgrove HMO fire safety requirements

Bromsgrove publishes its own HMO fire safety standard, "Redditch & Bromsgrove's Amenity Standards Guide" (Updated 2020). It is based on the Homestamp standard, which 10 other councils use too.

Is a fire risk assessment needed for the licence?

Not stated by the council

We could not find the council saying whether it wants to see your fire risk assessment. Fire safety law still says the landlord of an HMO must have one.

Who can carry it out?

No rule on who writes it

The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.

Which standard applies?

Redditch & Bromsgrove's Amenity Standards Guide

Published Updated 2020.

Read the council's document →

When did we last check?

14 October 2026

We re-check every council's documents each month and update this page when they change.

What Bromsgrove expects in 3 typical HMOs

Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.

2-storey shared house, 5 tenants

Fire alarm system
Grade D2, LD2, plus a linked smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Required
Fire blanket in the kitchen
Required
Fire extinguishers
Not required

3-storey shared house, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Required
Fire blanket in the kitchen
Required
Fire extinguishers
Not required

3-storey bedsits with cooking in rooms, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked heat detector and a standalone smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Required
Fire blanket in the kitchen
Required
Fire extinguishers
Not required
  • Grade D2 (mains alarms with a replaceable backup battery)
  • Grade A (a panel system with call points)
  • LD2 (escape route plus rooms where fires are likely to start)

In the council's own words

The wording these requirements come from, quoted from the published documents.

Fire alarms

Council's own standard

“Installing an automatic fire detection and warning system in accordance with British Standard S839 Part 6 : 2004 Grade A, giving a category LD2 level of coverage (ie smoke detectors in each bedroom, communal living room, hall, landings and any walk-in cupboards and cellars (where appropriate) plus heat detectors in each shared kitchen all linked to a control panel). ... Installing an interlinked automatic fire detection and warning system in accordance with British Standard 5839 Part 6: 2004 Grade D giving a category LD2 level of coverage. No control panel is required”
Redditch & Bromsgrove's Amenity Standards Guide, Updated 2020

Fire doors

Council's own standard

“A protected escape route which is created by fitting half hour fire resisting self-closing fire doors to all risk rooms adjoining the communal escape route ... The fitting of a half hour fire resisting self-closing door to the kitchen only is however acceptable where all bedroom windows at first floor level meet with escape window specifications. ... The protected route and emergency lighting system are as for a 3 storey property”
Redditch & Bromsgrove's Amenity Standards Guide, Updated 2020

Escape route

Council's own standard

“A protected escape route which is created by fitting half hour fire resisting self-closing fire doors to all risk rooms adjoining the communal escape route ... The fitting of a half hour fire resisting self-closing door to the kitchen only is however acceptable where all bedroom windows at first floor level meet with escape window specifications. ... The protected route and emergency lighting system are as for a 3 storey property”
Redditch & Bromsgrove's Amenity Standards Guide, Updated 2020

Kitchen heat detector

LACORS national guide

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Emergency lighting

Council's own standard

“Installing an emergency lighting system to the communal escape route in accordance with BS5266. ... Installing an emergency lighting system to the communal escape route in accordance with British Standard 5266.”
Redditch & Bromsgrove's Amenity Standards Guide, Updated 2020

Fire extinguishers

Shared regional standard

“Landlords should consider the following points where extinguishers are to be provided ... devices. Unless a fire is very small, it is best ... on balance to encourage people simply to”
A Guide to Fire and Security Protection in Multi-Occupied Residential Properties (Homestamp Consortium), Revision 2015

Spotted something out of date? Tell us and we will check it.

Common questions

Do I need a fire risk assessment for a Bromsgrove HMO licence?
We could not find the council saying whether it wants to see your fire risk assessment. Fire safety law still says the landlord of an HMO must have one.
Can I do my own HMO fire risk assessment in Bromsgrove?
The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.
Which fire safety standard does Bromsgrove use for HMOs?
Bromsgrove publishes "Redditch & Bromsgrove's Amenity Standards Guide" (Updated 2020).
What fire alarm does a 3-storey shared house need in Bromsgrove?
For a typical 3-storey shared house with 6 tenants, Bromsgrove's rules work out at Grade A, LD2, plus a linked smoke alarm in each letting. Your house may need something different depending on its layout, so check it properly with a fire risk assessment.

Check your Bromsgrove HMO against the council's standard

Answer plain-English questions about your house and get a fire risk assessment report built on Bromsgrove's rules. £45, no subscription.