West Midlands

Wychavon HMO fire safety requirements

Wychavon publishes its own HMO fire safety standard, "Standards for Houses in Multiple Occupation (HMO), POL0016 (Malvern Hills and Wychavon District Councils)" (Implemented March 2026).

Is a fire risk assessment needed for the licence?

Yes, with your licence application

The council lists a written fire risk assessment as one of the documents you send with your HMO licence application.

Who can carry it out?

A "competent person"

The council says a "competent person" must carry it out. In fire safety law that means someone with enough training, experience or knowledge to assess the house properly. A careful landlord can meet that.

Which standard applies?

Standards for Houses in Multiple Occupation (HMO), POL0016 (Malvern Hills and Wychavon District Councils)

Published Implemented March 2026.

Read the council's document →

When did we last check?

5 October 2026

We re-check every council's documents each month and update this page when they change.

What Wychavon expects in 3 typical HMOs

Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.

2-storey shared house, 5 tenants

Fire alarm system
Grade D1, LD3
Fire doors on bedrooms
Not required
Fire door on the kitchen
Not required
Protected escape route
Not required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Not required

3-storey shared house, 6 tenants

Fire alarm system
Grade D1, LD3
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Not required

3-storey bedsits with cooking in rooms, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked heat detector and a standalone smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Required
  • Grade D1 (mains alarms with a sealed backup battery)
  • Grade A (a panel system with call points)
  • LD3 (escape route only)
  • LD2 (escape route plus rooms where fires are likely to start)

In the council's own words

The wording these requirements come from, quoted from the published documents.

Fire alarms

Shared regional standard

“It is not recommended that a Grade D2 system is installed in rented dwellings. ... details what the councils will accept as the minimum in terms of the grade and coverage of ... Shared Grade D1: LD3 system ... integral battery pack back-up ... including bedrooms, living rooms, kitchen (heat ... Grade D1: LD2 coverage in ... Interlinked heat alarms with integral battery back-up located in each bedsit ... Additional non-interlinked smoke alarms with integral battery back-up in each bedsit ... Grade A: LD2 coverage in the ... Grade D1 smoke alarms in each bedsit to protect the sleeping occupants (non-interlinked)”
Standards for Houses in Multiple Occupation (HMO), POL0016 (Malvern Hills and Wychavon District Councils), Implemented March 2026

Fire doors

LACORS national guide

“30-minute protected route note 8, is required, including 30-minute fire-resisting construction and FD30 doors to all risk rooms (without smoke seals ... 30-minute fire-resisting construction and FD30S doors to all risk rooms. Travel distance must not be excessive”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Escape route

Shared regional standard

“All properties must have a protected fire escape route where all occupants are able to escape safely in the event of a fire. ... No requirement for full 30-minute protected ... route but the escape route should have ... 30-minute protected route is required, ... where construction standards are poor, travel distances are long or other high risk factors are present, a 30-minute protected route and 30-minute fire doors may be required.”
Standards for Houses in Multiple Occupation (HMO), POL0016 (Malvern Hills and Wychavon District Councils), Implemented March 2026

Kitchen heat detector

LACORS national guide

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Emergency lighting

LACORS national guide

“Emergency escape lighting required only if the route is long or complex or where there is no effective borrowed light ... Shared house HMO of five or six storeys (shared cooking facilities) Conventional lighting and emergency escape lighting”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Fire extinguishers

Shared regional standard

“Where kitchen facilities are provided within bedrooms or bedsitting rooms, they should be situated in a distinct kitchen area ... i. A fire blanket and suitable small fire extinguisher.”
Standards for Houses in Multiple Occupation (HMO), POL0016 (Malvern Hills and Wychavon District Councils), Implemented March 2026

Spotted something out of date? Tell us and we will check it.

Not in Wychavon?

Councils using the same standard as Wychavon

Common questions

Do I need a fire risk assessment for a Wychavon HMO licence?
The council lists a written fire risk assessment as one of the documents you send with your HMO licence application.
Can I do my own HMO fire risk assessment in Wychavon?
The council says a "competent person" must carry it out. In fire safety law that means someone with enough training, experience or knowledge to assess the house properly. A careful landlord can meet that.
Which fire safety standard does Wychavon use for HMOs?
Wychavon publishes "Standards for Houses in Multiple Occupation (HMO), POL0016 (Malvern Hills and Wychavon District Councils)" (Implemented March 2026).
What fire alarm does a 3-storey shared house need in Wychavon?
For a typical 3-storey shared house with 6 tenants, Wychavon's rules work out at Grade D1, LD3. Your house may need something different depending on its layout, so check it properly with a fire risk assessment.

Check your Wychavon HMO against the council's standard

Answer plain-English questions about your house and get a fire risk assessment report built on Wychavon's rules. £45, no subscription.