Malvern Hills and Wychavon HMO fire safety standards

Malvern Hills and Wychavon district councils publish one Standards for Houses in Multiple Occupation document (POL0016), in force from March 2026.

Read "Standards for Houses in Multiple Occupation (HMO), POL0016" (Implemented March 2026) →

What the Malvern Hills and Wychavon standard expects in 3 typical HMOs

Your council may have changed some of the detail, so check your council's own page below.

Requirement2-storey shared house, 5 tenants3-storey shared house, 6 tenants3-storey bedsits with cooking in rooms, 6 tenants
Fire alarm systemGrade D1, LD3Grade D1, LD3Grade A, LD2, plus a linked heat detector and a standalone smoke alarm in each letting
Fire doors on bedroomsNot requiredRequiredRequired
Fire door on the kitchenNot requiredRequiredRequired
Protected escape routeNot requiredRequiredRequired
Heat detector in the kitchenRequiredRequiredRequired
Emergency lightingNot requiredNot requiredNot required
Fire blanket in the kitchenRequiredRequiredRequired
Fire extinguishersNot requiredNot requiredRequired
  • Grade D1 (mains alarms with a sealed backup battery)
  • Grade A (a panel system with call points)
  • LD3 (escape route only)
  • LD2 (escape route plus rooms where fires are likely to start)

What the standard says

Fire alarms

Shared regional standard

“It is not recommended that a Grade D2 system is installed in rented dwellings. ... details what the councils will accept as the minimum in terms of the grade and coverage of ... Shared Grade D1: LD3 system ... integral battery pack back-up ... including bedrooms, living rooms, kitchen (heat ... Grade D1: LD2 coverage in ... Interlinked heat alarms with integral battery back-up located in each bedsit ... Additional non-interlinked smoke alarms with integral battery back-up in each bedsit ... Grade A: LD2 coverage in the ... Grade D1 smoke alarms in each bedsit to protect the sleeping occupants (non-interlinked)”
Standards for Houses in Multiple Occupation (HMO), POL0016 (Malvern Hills and Wychavon District Councils), Implemented March 2026

Escape route

Shared regional standard

“All properties must have a protected fire escape route where all occupants are able to escape safely in the event of a fire. ... No requirement for full 30-minute protected ... route but the escape route should have ... 30-minute protected route is required, ... where construction standards are poor, travel distances are long or other high risk factors are present, a 30-minute protected route and 30-minute fire doors may be required.”
Standards for Houses in Multiple Occupation (HMO), POL0016 (Malvern Hills and Wychavon District Councils), Implemented March 2026

Fire extinguishers

Shared regional standard

“Where kitchen facilities are provided within bedrooms or bedsitting rooms, they should be situated in a distinct kitchen area ... i. A fire blanket and suitable small fire extinguisher.”
Standards for Houses in Multiple Occupation (HMO), POL0016 (Malvern Hills and Wychavon District Councils), Implemented March 2026

Councils using the Malvern Hills and Wychavon standard

Every council's HMO fire safety standard →

Common questions

Which councils use the Malvern Hills and Wychavon standard?
2 councils: Malvern Hills, Wychavon.
Is the Malvern Hills and Wychavon standard stricter than LACORS?
In some places, yes. Where it asks for more than LACORS, you need to meet it. Where it asks for less, or says nothing, we use the LACORS minimum instead.