Skip to main content
£45 one-off •Your fire risk assessment in 35 minutes •No subscription

South East

Worthing HMO fire safety requirements

Worthing publishes its own HMO fire safety standard, "Compliance Guide for Houses in Multiple Occupation (HMOs) (Adur & Worthing Councils)" (V1.4 2023).

Is a fire risk assessment needed for the licence?

Yes, with your licence application

The council lists a written fire risk assessment as one of the documents you send with your HMO licence application.

Who can carry it out?

No rule on who writes it

The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.

Which standard applies?

Compliance Guide for Houses in Multiple Occupation (HMOs) (Adur & Worthing Councils)

Published V1.4 2023.

Read the council's document →

When did we last check?

29 September 2026

We re-check every council's documents each month and update this page when they change.

What Worthing expects in 3 typical HMOs

Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.

2-storey shared house, 5 tenants

Fire alarm system
Grade D2, LD3
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Not required

3-storey shared house, 6 tenants

Fire alarm system
Grade D2, LD3
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Not required

3-storey bedsits with cooking in rooms, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked heat detector and a standalone smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Not required
  • Grade D2 (mains alarms with a replaceable backup battery)
  • Grade A (a panel system with call points)
  • LD3 (escape route only)
  • LD2 (escape route plus rooms where fires are likely to start)

In the council's own words

The wording these requirements come from, quoted from the published documents.

Fire alarms

LACORS national guide

“Shared house HMO of three or four storeys (shared cooking facilities) Grade D: LD3 coverage + additional detection to the kitchen, lounge and any cellar containing a risk (interlinked) Shared house HMO of five or six storeys (shared cooking facilities) Grade A: LD2 coverage ... Bedsit HMO of one or two storeys with individual cooking facilities within bedsits A mixed system: Grade D: LD2 coverage in the common areas and heat detectors in bedsits (interlinked) Grade D smoke alarm in each bedsit to protect the sleeping occupants (non-interlinked) Bedsit HMO of three to six storeys with individual cooking facilities within bedsits A mixed system: Grade A: LD2 coverage in the common areas ... Where cooking facilities are sited in shared kitchen, not within bedsits: interlinked smoke alarms with integral battery backup located in each bedsit”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Fire doors

Shared regional standard

“A key element of the protected route is the doors that open on to the route from risk rooms. In most cases you will require a 30 minute fire rated door set, either an FD30S door set, or an FD30 door set.”
Compliance Guide for Houses in Multiple Occupation (HMOs) (Adur & Worthing Councils), V1.4 2023

Escape route

Shared regional standard

“You will be required to create a protected route out of the property from all habitable rooms. This will normally be a 30 minute protected route (to allow at least 30 minutes for occupants to be alerted to a fire and escape without harm)”
Compliance Guide for Houses in Multiple Occupation (HMOs) (Adur & Worthing Councils), V1.4 2023

Kitchen heat detector

LACORS national guide

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Emergency lighting

LACORS national guide

“Emergency escape lighting required only if the route is long or complex or where there is no effective borrowed light ... Shared house HMO of five or six storeys (shared cooking facilities) Conventional lighting and emergency escape lighting”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Fire extinguishers

Shared regional standard

“You are not required to provide fire extinguishers for residents to use, but in some cases there may be an organisational requirement to have them i.e. if you have staff on site.”
Compliance Guide for Houses in Multiple Occupation (HMOs) (Adur & Worthing Councils), V1.4 2023

Spotted something out of date? Tell us and we will check it.

Not in Worthing?

Councils using the same standard as Worthing

Common questions

Do I need a fire risk assessment for a Worthing HMO licence?
The council lists a written fire risk assessment as one of the documents you send with your HMO licence application.
Can I do my own HMO fire risk assessment in Worthing?
The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.
Which fire safety standard does Worthing use for HMOs?
Worthing publishes "Compliance Guide for Houses in Multiple Occupation (HMOs) (Adur & Worthing Councils)" (V1.4 2023).
What fire alarm does a 3-storey shared house need in Worthing?
For a typical 3-storey shared house with 6 tenants, Worthing's rules work out at Grade D2, LD3. Your house may need something different depending on its layout, so check it properly with a fire risk assessment.

Check your Worthing HMO against the council's standard

Answer plain-English questions about your house and get a fire risk assessment report built on Worthing's rules. £45, no subscription.