Staffordshire Moorlands HMO fire safety requirements

Staffordshire Moorlands publishes its own HMO fire safety standard, "Guidance on Standards for Houses in Multiple Occupation (High Peak and Staffordshire Moorlands)" (October 2018).

Is a fire risk assessment needed for the licence?

Expected, but not sent in

The council's guidance talks about fire risk assessments, but it does not ask you to send one with your application. Fire safety law still says you need one.

Who can carry it out?

No rule on who writes it

The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.

Which standard applies?

Guidance on Standards for Houses in Multiple Occupation (High Peak and Staffordshire Moorlands)

Published October 2018.

Read the council's document →

When did we last check?

15 October 2026

We re-check every council's documents each month and update this page when they change.

What Staffordshire Moorlands expects in 3 typical HMOs

Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.

2-storey shared house, 5 tenants

Fire alarm system
Grade D2, LD3
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Required

3-storey shared house, 6 tenants

Fire alarm system
Grade D2, LD3
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Required
Fire blanket in the kitchen
Required
Fire extinguishers
Required

3-storey bedsits with cooking in rooms, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked heat detector and a standalone smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Required
Fire blanket in the kitchen
Required
Fire extinguishers
Required
  • Grade D2 (mains alarms with a replaceable backup battery)
  • Grade A (a panel system with call points)
  • LD3 (escape route only)
  • LD2 (escape route plus rooms where fires are likely to start)

In the council's own words

The wording these requirements come from, quoted from the published documents.

Fire alarms

LACORS national guide

“Shared house HMO of three or four storeys (shared cooking facilities) Grade D: LD3 coverage + additional detection to the kitchen, lounge and any cellar containing a risk (interlinked) Shared house HMO of five or six storeys (shared cooking facilities) Grade A: LD2 coverage ... Bedsit HMO of one or two storeys with individual cooking facilities within bedsits A mixed system: Grade D: LD2 coverage in the common areas and heat detectors in bedsits (interlinked) Grade D smoke alarm in each bedsit to protect the sleeping occupants (non-interlinked) Bedsit HMO of three to six storeys with individual cooking facilities within bedsits A mixed system: Grade A: LD2 coverage in the common areas ... Where cooking facilities are sited in shared kitchen, not within bedsits: interlinked smoke alarms with integral battery backup located in each bedsit”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Fire doors

Council's own standard

“all doors opening onto the communal stairs and landings must be of 30 minute fire resisting construction. This includes all bedroom doors”
Guidance on Standards for Houses in Multiple Occupation (High Peak and Staffordshire Moorlands), October 2018

Escape route

Council's own standard

“The stairway to the house must be enclosed by half hour fire resisting construction, that is the ceiling, walls and floor.”
Guidance on Standards for Houses in Multiple Occupation (High Peak and Staffordshire Moorlands), October 2018

Kitchen heat detector

LACORS national guide

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Emergency lighting

Council's own standard

“This is not usually required in two storey houses. In houses with three or more storeys, emergency lighting to BS 5266 shall be provided to the escape routes”
Guidance on Standards for Houses in Multiple Occupation (High Peak and Staffordshire Moorlands), October 2018

Fire extinguishers

Council's own standard

“Provide an approved minimum 2kg dry powder or multi-risk extinguisher within the communal kitchen.”
Guidance on Standards for Houses in Multiple Occupation (High Peak and Staffordshire Moorlands), October 2018

Spotted something out of date? Tell us and we will check it.

Not in Staffordshire Moorlands?

Common questions

Do I need a fire risk assessment for a Staffordshire Moorlands HMO licence?
The council's guidance talks about fire risk assessments, but it does not ask you to send one with your application. Fire safety law still says you need one.
Can I do my own HMO fire risk assessment in Staffordshire Moorlands?
The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.
Which fire safety standard does Staffordshire Moorlands use for HMOs?
Staffordshire Moorlands publishes "Guidance on Standards for Houses in Multiple Occupation (High Peak and Staffordshire Moorlands)" (October 2018). Like most councils, it builds on the national LACORS guide.
What fire alarm does a 3-storey shared house need in Staffordshire Moorlands?
For a typical 3-storey shared house with 6 tenants, Staffordshire Moorlands's rules work out at Grade D2, LD3. Your house may need something different depending on its layout, so check it properly with a fire risk assessment.