Rother HMO fire safety requirements

Rother publishes its own HMO fire safety standard, "Guidance for amenities in Houses in Multiple Occupation (CIEH Sussex Housing Group)" (October 2015, amended 2018). It is based on the Sussex standard, which 5 other councils use too.

Is a fire risk assessment needed for the licence?

Yes, as a licence condition

You need a written fire risk assessment as a condition of the licence, and the council can ask to see it at any time.

Who can carry it out?

A qualified fire risk assessor

The council says the fire risk assessment must be carried out by a qualified or experienced fire risk assessor. A landlord's own assessment is unlikely to be accepted for the licence.

Which standard applies?

Guidance for amenities in Houses in Multiple Occupation (CIEH Sussex Housing Group)

Published October 2015, amended 2018.

Read the council's document →

When did we last check?

14 October 2026

We re-check every council's documents each month and update this page when they change.

Rother asks for a qualified fire risk assessor, so a self-assessment (including ours) is unlikely to be accepted for your licence. Find a qualified assessor →

What Rother expects in 3 typical HMOs

Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.

2-storey shared house, 5 tenants

Fire alarm system
Grade D2, LD3
Fire doors on bedrooms
Not required
Fire door on the kitchen
Not required
Protected escape route
Not required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Not advised

3-storey shared house, 6 tenants

Fire alarm system
Grade D2, LD3
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Not advised

3-storey bedsits with cooking in rooms, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked heat detector and a standalone smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Not advised
  • Grade D2 (mains alarms with a replaceable backup battery)
  • Grade A (a panel system with call points)
  • LD3 (escape route only)
  • LD2 (escape route plus rooms where fires are likely to start)

In the council's own words

The wording these requirements come from, quoted from the published documents.

Fire alarms

LACORS national guide

“Shared house HMO of three or four storeys (shared cooking facilities) Grade D: LD3 coverage + additional detection to the kitchen, lounge and any cellar containing a risk (interlinked) Shared house HMO of five or six storeys (shared cooking facilities) Grade A: LD2 coverage ... Bedsit HMO of one or two storeys with individual cooking facilities within bedsits A mixed system: Grade D: LD2 coverage in the common areas and heat detectors in bedsits (interlinked) Grade D smoke alarm in each bedsit to protect the sleeping occupants (non-interlinked) Bedsit HMO of three to six storeys with individual cooking facilities within bedsits A mixed system: Grade A: LD2 coverage in the common areas ... Where cooking facilities are sited in shared kitchen, not within bedsits: interlinked smoke alarms with integral battery backup located in each bedsit”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Fire doors

LACORS national guide

“30-minute protected route note 8, is required, including 30-minute fire-resisting construction and FD30 doors to all risk rooms (without smoke seals ... 30-minute fire-resisting construction and FD30S doors to all risk rooms. Travel distance must not be excessive”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Escape route

LACORS national guide

“No requirement for full 30-minute protected route note 7, but the escape route should have sound, traditional construction and should not pass through risk rooms ... 30-minute protected route note 8, is required, including 30-minute fire-resisting construction”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Kitchen heat detector

LACORS national guide

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Emergency lighting

LACORS national guide

“Emergency escape lighting required only if the route is long or complex or where there is no effective borrowed light ... Shared house HMO of five or six storeys (shared cooking facilities) Conventional lighting and emergency escape lighting”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Fire extinguishers

Shared regional standard

“The LACORS guide recommends the provision of fire extinguishers on all floors, however, local authorities do not normally require them. This is due to the need for training, for regular maintenance and problems with extinguishers being maliciously set off or played with.”
Guidance for amenities in Houses in Multiple Occupation (CIEH Sussex Housing Group, Rother District Council), October 2015, amended 2018

Spotted something out of date? Tell us and we will check it.

Not in Rother?

Councils using the same standard as Rother

Common questions

Do I need a fire risk assessment for a Rother HMO licence?
You need a written fire risk assessment as a condition of the licence, and the council can ask to see it at any time.
Can I do my own HMO fire risk assessment in Rother?
The council says the fire risk assessment must be carried out by a qualified or experienced fire risk assessor. A landlord's own assessment is unlikely to be accepted for the licence.
Which fire safety standard does Rother use for HMOs?
Rother publishes "Guidance for amenities in Houses in Multiple Occupation (CIEH Sussex Housing Group)" (October 2015, amended 2018).
What fire alarm does a 3-storey shared house need in Rother?
For a typical 3-storey shared house with 6 tenants, Rother's rules work out at Grade D2, LD3. Your house may need something different depending on its layout, so check it properly with a fire risk assessment.