Arun HMO fire safety requirements

Arun publishes its own HMO fire safety standard, "Standards for houses in multiple occupation: Fire precautionary facilities and fire safety (Arun District Council web page)" (Not dated). It is based on the Sussex standard, which 5 other councils use too.

Is a fire risk assessment needed for the licence?

Yes, with your licence application

The council lists a written fire risk assessment as one of the documents you send with your HMO licence application.

Who can carry it out?

A "competent person"

The council says a "competent person" must carry it out. In fire safety law that means someone with enough training, experience or knowledge to assess the house properly. A careful landlord can meet that.

Which standard applies?

Standards for houses in multiple occupation: Fire precautionary facilities and fire safety (Arun District Council web page)

Published Not dated.

Read the council's document →

When did we last check?

12 October 2026

We re-check every council's documents each month and update this page when they change.

What Arun expects in 3 typical HMOs

Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.

2-storey shared house, 5 tenants

Fire alarm system
Grade D1, LD3
Fire doors on bedrooms
Not required
Fire door on the kitchen
Not required
Protected escape route
Not required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Not advised

3-storey shared house, 6 tenants

Fire alarm system
Grade D1, LD3
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Required
Fire blanket in the kitchen
Required
Fire extinguishers
Not advised

3-storey bedsits with cooking in rooms, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked heat detector and a standalone smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Required
Fire blanket in the kitchen
Required
Fire extinguishers
Not advised
  • Grade D1 (mains alarms with a sealed backup battery)
  • Grade A (a panel system with call points)
  • LD3 (escape route only)
  • LD2 (escape route plus rooms where fires are likely to start)

In the council's own words

The wording these requirements come from, quoted from the published documents.

Fire alarms

Council's own standard

“Required in smaller properties ... This system has one or more interlinked, mains-powered smoke and/or heat alarms each with a tamper-proof integral battery standby supply”
Standards for houses in multiple occupation: Fire precautionary facilities and fire safety (Arun District Council web page), Not dated

Fire doors

LACORS national guide

“30-minute protected route note 8, is required, including 30-minute fire-resisting construction and FD30 doors to all risk rooms (without smoke seals ... 30-minute fire-resisting construction and FD30S doors to all risk rooms. Travel distance must not be excessive”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Escape route

LACORS national guide

“No requirement for full 30-minute protected route note 7, but the escape route should have sound, traditional construction and should not pass through risk rooms ... 30-minute protected route note 8, is required, including 30-minute fire-resisting construction”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Kitchen heat detector

LACORS national guide

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Emergency lighting

Council's own standard

“Emergency escape lighting is required in all converted domestic buildings with three or more storeys, and in some circumstances, emergency escape lighting may be required if the escape route is complex and/or there is no effective borrowed light in buildings containing fewer than three storeys. In any circumstance, it is recommended that emergency escape lighting is provided in any building where there would be little or no light to clearly see the escape route”
Standards for houses in multiple occupation: Fire precautionary facilities and fire safety (Arun District Council web page), Not dated

Fire extinguishers

Shared regional standard

“The LACORS guide recommends the provision of fire extinguishers on all floors, however, local authorities do not normally require them. This is due to the need for training, for regular maintenance and problems with extinguishers being maliciously set off or played with.”
Guidance for amenities in Houses in Multiple Occupation (CIEH Sussex Housing Group, Rother District Council), October 2015, amended 2018

Spotted something out of date? Tell us and we will check it.

Not in Arun?

Councils using the same standard as Arun

Common questions

Do I need a fire risk assessment for a Arun HMO licence?
The council lists a written fire risk assessment as one of the documents you send with your HMO licence application.
Can I do my own HMO fire risk assessment in Arun?
The council says a "competent person" must carry it out. In fire safety law that means someone with enough training, experience or knowledge to assess the house properly. A careful landlord can meet that.
Which fire safety standard does Arun use for HMOs?
Arun publishes "Standards for houses in multiple occupation: Fire precautionary facilities and fire safety (Arun District Council web page)" (Not dated).
What fire alarm does a 3-storey shared house need in Arun?
For a typical 3-storey shared house with 6 tenants, Arun's rules work out at Grade D1, LD3. Your house may need something different depending on its layout, so check it properly with a fire risk assessment.

Check your Arun HMO against the council's standard

Answer plain-English questions about your house and get a fire risk assessment report built on Arun's rules. £45, no subscription.