North Tyneside HMO fire safety requirements

North Tyneside publishes its own HMO fire safety standard, "Guidance for Landlords on HMO Standards in North Tyneside" (Undated (after October 2018)). It is based on the Tyne and Wear standard, which 2 other councils use too.

Is a fire risk assessment needed for the licence?

Expected, but not sent in

The council's guidance talks about fire risk assessments, but it does not ask you to send one with your application. Fire safety law still says you need one.

Who can carry it out?

No rule on who writes it

The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.

Which standard applies?

Guidance for Landlords on HMO Standards in North Tyneside

Published Undated (after October 2018).

Read the council's document →

When did we last check?

4 October 2026

We re-check every council's documents each month and update this page when they change.

What North Tyneside expects in 3 typical HMOs

Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.

2-storey shared house, 5 tenants

Fire alarm system
Grade D2, LD2
Fire doors on bedrooms
Not required
Fire door on the kitchen
Required
Protected escape route
Not required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended

3-storey shared house, 6 tenants

Fire alarm system
Grade D2, LD1
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended

3-storey bedsits with cooking in rooms, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked heat detector and a standalone smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended
  • Grade D2 (mains alarms with a replaceable backup battery)
  • Grade A (a panel system with call points)
  • LD2 (escape route plus rooms where fires are likely to start)
  • LD1 (alarms in all rooms and on the escape route)

In the council's own words

The wording these requirements come from, quoted from the published documents.

Fire alarms

Shared regional standard

“Grade D, LD1 system i.e. smoke alarms on the escape route on all levels, in all risk rooms in which a fire might start (e.g. communal living room, utility room, all bedrooms) ... Grade D, LD2 system i.e. smoke alarms on the escape route on all levels, in all communal risk rooms (e.g. living room, utility room) ... For bedsits or properties of more than 4 storeys, or those housing”
Guidance for Landlords on HMO Standards in North Tyneside (North Tyneside Council), Undated (after October 2018)

Fire doors

LACORS national guide

“30-minute protected route note 8, is required, including 30-minute fire-resisting construction and FD30 doors to all risk rooms (without smoke seals ... 30-minute fire-resisting construction and FD30S doors to all risk rooms. Travel distance must not be excessive”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Escape route

LACORS national guide

“No requirement for full 30-minute protected route note 7, but the escape route should have sound, traditional construction and should not pass through risk rooms ... 30-minute protected route note 8, is required, including 30-minute fire-resisting construction”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Kitchen heat detector

LACORS national guide

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Emergency lighting

Shared regional standard

“Emergency lighting to be provided if escape route is long, complex or lacks sufficient borrowed light”
Guidance for Landlords on HMO Standards in North Tyneside (North Tyneside Council), Undated (after October 2018)

Fire extinguishers

LACORS national guide

“a simple multi-purpose extinguisher is recommended on each floor in the common parts of HMOs and buildings containing flats.”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Spotted something out of date? Tell us and we will check it.

Not in North Tyneside?

Councils using the same standard as North Tyneside

Common questions

Do I need a fire risk assessment for a North Tyneside HMO licence?
The council's guidance talks about fire risk assessments, but it does not ask you to send one with your application. Fire safety law still says you need one.
Can I do my own HMO fire risk assessment in North Tyneside?
The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.
Which fire safety standard does North Tyneside use for HMOs?
North Tyneside publishes "Guidance for Landlords on HMO Standards in North Tyneside" (Undated (after October 2018)).
What fire alarm does a 3-storey shared house need in North Tyneside?
For a typical 3-storey shared house with 6 tenants, North Tyneside's rules work out at Grade D2, LD1. Your house may need something different depending on its layout, so check it properly with a fire risk assessment.

Check your North Tyneside HMO against the council's standard