Gateshead HMO fire safety requirements

Gateshead publishes its own HMO fire safety standard, "Mandatory Licensing of Houses in Multiple Occupation: Policy and Guide for Landlords and Agents, Appendix C HMO Property Standard (Gateshead Council)" (2025). It is based on the Tyne and Wear standard, which 2 other councils use too.

Is a fire risk assessment needed for the licence?

Yes, as a licence condition

You need a written fire risk assessment as a condition of the licence, and the council can ask to see it at any time.

Who can carry it out?

No rule on who writes it

The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.

Which standard applies?

Mandatory Licensing of Houses in Multiple Occupation: Policy and Guide for Landlords and Agents, Appendix C HMO Property Standard (Gateshead Council)

Published 2025.

Read the council's document →

When did we last check?

13 October 2026

We re-check every council's documents each month and update this page when they change.

What Gateshead expects in 3 typical HMOs

Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.

2-storey shared house, 5 tenants

Fire alarm system
Grade D2, LD2
Fire doors on bedrooms
Not required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended

3-storey shared house, 6 tenants

Fire alarm system
Grade A, LD2
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended

3-storey bedsits with cooking in rooms, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked heat detector and a standalone smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended
  • Grade D2 (mains alarms with a replaceable backup battery)
  • Grade A (a panel system with call points)
  • LD2 (escape route plus rooms where fires are likely to start)

In the council's own words

The wording these requirements come from, quoted from the published documents.

Fire alarms

Council's own standard

“A mixed system, Grade A, LD2 system comprised of interlinked smoke alarms on the escape route on all levels, in all risk rooms in which a fire might start ... A mixed system, Grade D, LD2 system comprised of interlinked smoke alarms on the escape route on all levels, in all bedrooms”
Mandatory Licensing of Houses in Multiple Occupation: Policy and Guide for Landlords and Agents (Gateshead Council), 2025

Fire doors

LACORS national guide

“30-minute protected route note 8, is required, including 30-minute fire-resisting construction and FD30 doors to all risk rooms (without smoke seals ... 30-minute fire-resisting construction and FD30S doors to all risk rooms. Travel distance must not be excessive”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Escape route

Council's own standard

“A 30 minute protected route is required including 30 minute fire resisting construction and FD30S doors to all risk rooms”
Mandatory Licensing of Houses in Multiple Occupation: Policy and Guide for Landlords and Agents (Gateshead Council), 2025

Kitchen heat detector

LACORS national guide

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Emergency lighting

Shared regional standard

“Emergency lighting to be provided if escape route is long, complex or lacks sufficient borrowed light”
Guidance for Landlords on HMO Standards in North Tyneside (North Tyneside Council), Undated (after October 2018)

Fire extinguishers

LACORS national guide

“a simple multi-purpose extinguisher is recommended on each floor in the common parts of HMOs and buildings containing flats.”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Spotted something out of date? Tell us and we will check it.

Not in Gateshead?

Councils using the same standard as Gateshead

Common questions

Do I need a fire risk assessment for a Gateshead HMO licence?
You need a written fire risk assessment as a condition of the licence, and the council can ask to see it at any time.
Can I do my own HMO fire risk assessment in Gateshead?
The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.
Which fire safety standard does Gateshead use for HMOs?
Gateshead publishes "Mandatory Licensing of Houses in Multiple Occupation: Policy and Guide for Landlords and Agents, Appendix C HMO Property Standard (Gateshead Council)" (2025).
What fire alarm does a 3-storey shared house need in Gateshead?
For a typical 3-storey shared house with 6 tenants, Gateshead's rules work out at Grade A, LD2. Your house may need something different depending on its layout, so check it properly with a fire risk assessment.

Check your Gateshead HMO against the council's standard

Answer plain-English questions about your house and get a fire risk assessment report built on Gateshead's rules. £45, no subscription.