Liverpool HMO fire safety requirements

Liverpool publishes its own HMO fire safety standard, "Houses in Multiple Occupation - Standards and Management" (February 2022).

Is a fire risk assessment needed for the licence?

Yes, with your licence application

The council lists a written fire risk assessment as one of the documents you send with your HMO licence application.

Who can carry it out?

A qualified fire risk assessor

The council says the fire risk assessment must be carried out by a qualified or experienced fire risk assessor. A landlord's own assessment is unlikely to be accepted for the licence.

Which standard applies?

Houses in Multiple Occupation - Standards and Management

Published February 2022.

Read the council's document →

When did we last check?

14 October 2026

We re-check every council's documents each month and update this page when they change.

Liverpool asks for a qualified fire risk assessor, so a self-assessment (including ours) is unlikely to be accepted for your licence. Find a qualified assessor →

What Liverpool expects in 3 typical HMOs

Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.

2-storey shared house, 5 tenants

Fire alarm system
Grade D2, LD3
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended

3-storey shared house, 6 tenants

Fire alarm system
Grade D2, LD3
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended

3-storey bedsits with cooking in rooms, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked heat detector and a standalone smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended
  • Grade D2 (mains alarms with a replaceable backup battery)
  • Grade A (a panel system with call points)
  • LD3 (escape route only)
  • LD2 (escape route plus rooms where fires are likely to start)

In the council's own words

The wording these requirements come from, quoted from the published documents.

Fire alarms

LACORS national guide

“Shared house HMO of three or four storeys (shared cooking facilities) Grade D: LD3 coverage + additional detection to the kitchen, lounge and any cellar containing a risk (interlinked) Shared house HMO of five or six storeys (shared cooking facilities) Grade A: LD2 coverage ... Bedsit HMO of one or two storeys with individual cooking facilities within bedsits A mixed system: Grade D: LD2 coverage in the common areas and heat detectors in bedsits (interlinked) Grade D smoke alarm in each bedsit to protect the sleeping occupants (non-interlinked) Bedsit HMO of three to six storeys with individual cooking facilities within bedsits A mixed system: Grade A: LD2 coverage in the common areas ... Where cooking facilities are sited in shared kitchen, not within bedsits: interlinked smoke alarms with integral battery backup located in each bedsit”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Fire doors

Council's own standard

“Doors that open onto the protected route (i.e. kitchen, lounge, dining room and bedroom doors) to be Fire Doors installed and maintained in accordance with the manufacturer’s instructions”
Houses in Multiple Occupation - Standards and Management (Liverpool City Council), February 2022

Escape route

Council's own standard

“Below is a guide to various general fire safety standards required for HMO’s. This is not intended to cover all fire safety matters required ... Protection of the internal structure to provide Half-hour fire resistant separation between each floor level, adjoining units of accommodation and the protected escape route (i.e. communal hallway, landings, staircase).”
Houses in Multiple Occupation - Standards and Management (Liverpool City Council), February 2022

Kitchen heat detector

LACORS national guide

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Emergency lighting

Council's own standard

“Below is a guide to various general fire safety standards required for HMO’s. This is not intended to cover all fire safety matters required ... A non-maintained Emergency Lighting system conforming to BS5266 Part 1”
Houses in Multiple Occupation - Standards and Management (Liverpool City Council), February 2022

Fire extinguishers

LACORS national guide

“a simple multi-purpose extinguisher is recommended on each floor in the common parts of HMOs and buildings containing flats.”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Spotted something out of date? Tell us and we will check it.

Common questions

Do I need a fire risk assessment for a Liverpool HMO licence?
The council lists a written fire risk assessment as one of the documents you send with your HMO licence application.
Can I do my own HMO fire risk assessment in Liverpool?
The council says the fire risk assessment must be carried out by a qualified or experienced fire risk assessor. A landlord's own assessment is unlikely to be accepted for the licence.
Which fire safety standard does Liverpool use for HMOs?
Liverpool publishes "Houses in Multiple Occupation - Standards and Management" (February 2022). Like most councils, it builds on the national LACORS guide.
What fire alarm does a 3-storey shared house need in Liverpool?
For a typical 3-storey shared house with 6 tenants, Liverpool's rules work out at Grade D2, LD3. Your house may need something different depending on its layout, so check it properly with a fire risk assessment.