Skip to main content

HMO fire risk assessment

Fire risk assessments for St Albans HMOs.

Every St Albans HMO needs a written fire risk assessment. Do yours online to BS 9792:2025, and see what St Albans's own fire safety rules mean for your house.

Skip the £200–£500 assessor bill. Built on the guidance councils use, for £45.

BS 9792:2025 methodBuilt on the LACORS guideWorks offline on-siteInstant PDF report

Refund guarantee: full refund if your council rejects our report’s format or the standard it’s written to. Terms apply.

£45 one-off · PDF report · no subscription

St AlbansSt Albans council area
Council rulesOwn standard, 2019
Typical assessor cost£200–£500
With FRASafe£45
TurnaroundSame day

Written by Bradley, Founder of FRASafeCouncil rules last checked 14 October 2026How we check →

East of England

St Albans's HMO fire safety rules

St Albans publishes its own HMO fire safety standard, "SADC HMO Amenity Standards, section 5 Fire Precautionary Facilities" (2019). It is based on the Hertfordshire standard, which 3 other councils use too. FRASafe's assessment follows BS 9792:2025 and LACORS. Below is what St Albans's rules ask for in a typical house, so you know what to expect.

Assessment for the licence
Yes, with your licence application
Who can carry it out
No rule on who writes it
Last checked
14 October 2026

Running an HMO in St Albans

The local rules and contacts that sit alongside your fire risk assessment, each taken from the council's or fire service's own website.

Fire and rescue service

Hertfordshire Fire and Rescue Service covers St Albans.

Source: hertfordshire.gov.uk
Licence fee

A new HMO licence from St Albans costs £207 per person, with a minimum fee of £1,035.

Show the official wording
“The fee for processing HMO licence applications is £207 per person with a minimum fee of £1035.”
Source: stalbans.gov.uk
Licensed HMOs

76 HMOs on St Albans's licence register (October 2026).

Show the official wording
“Updated - October 2026”
Source: stalbans.gov.uk

Applying for or renewing your St Albans HMO licence? St Albans wants a written fire risk assessment with your application.

Get my fire risk assessment

Worked example

What your St Albans fire risk assessment will check

A typical 3-storey shared house with 6 tenants, run through St Albans's rules. Each item shows the wording it comes from, and what your action plan says if the house is missing it. Your own house may need more or less, which is what the assessment works out.

Fire alarm

Required

A linked fire alarm system (Grade A, LD2, plus a linked smoke alarm in each letting)

“BS5839-6 (2019) has changed the requirements for HMO premises of 1-2 stories (below 200m2) for new or materially altered premises, which will now require a grade D category LD1 rather than LD2.”
Hertfordshire Guide to Fire Safety in Houses in Multiple Occupation, Version 3 with 2019 revision (St Albans copy), September 2015, revised 2019

If it's missing: High priority in your action plan

The fire alarm is Grade F. This house needs a Grade A system with LD2 coverage. Have a qualified alarm engineer upgrade it to BS 5839-1. Required by SADC HMO Amenity Standards (St Albans City and District Council) (2019).

Fire doors

Required

Fire doors with self-closers on every bedroom and the kitchen

“Ensure that there are self-closing fire doors that provide 30 minutes fire and smoke protection (FD30S) on all bedrooms, kitchens and living rooms.”
SADC HMO Amenity Standards (St Albans City and District Council), 2019

If it's missing: High priority in your action plan

Not every bedroom door is a fire door with a self-closer. Fit FD30 fire doors with self-closers to all bedrooms. Required by SADC HMO Amenity Standards (St Albans City and District Council) (2019).

Escape route

Required

A protected escape route, with the hall and stairs giving 30 minutes' fire resistance

“All HMOs shall be provided with an adequate protected means of escape from fire, together with other fire precautions including so far as necessary, a fire detection and warning system with emergency lighting to the satisfaction of the inspecting officer.”
SADC HMO Amenity Standards (St Albans City and District Council), 2019

If it's missing: High priority in your action plan

The hallway and stairs are not confirmed as a 30-minute protected route. Make good any holes or open-plan gaps so walls and ceilings give 30 minutes' fire resistance. Required by SADC HMO Amenity Standards (St Albans City and District Council) (2019).

Kitchen heat detector

Required

A linked heat detector in the kitchen

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

If it's missing: High priority in your action plan

Not every kitchen has a linked heat alarm. Fit an interlinked heat alarm in each kitchen. Required by LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing (July 2008).

Emergency lighting

Required

Emergency lighting on the escape route

“Arrange for the installation of suitable and sufficient emergency lighting to provide adequate coverage to the protected fire escape route. The number and position of any luminaries should be determined by your fire risk assessment.”
SADC HMO Amenity Standards (St Albans City and District Council), 2019

If it's missing: High priority in your action plan

The escape route needs emergency lighting and it is missing or damaged. Install or repair emergency lighting to BS 5266-1. Required by SADC HMO Amenity Standards (St Albans City and District Council) (2019).

Spotted something out of date? Tell us and we will check it.

How it works

From Blank Screen to Finished Report in 35 Minutes

Produce a BS 9792:2025 HMO fire risk assessment, checked against the LACORS housing fire safety guide that most councils use.

You do not need to be a fire-safety expert. FRASafe turns the legal requirements into plain-English questions and builds the report for you.

1

Complete the assessment

Answer structured questions covering fire hazards, means of escape, fire detection, fire doors, and more, mapped to BS 9792:2025 and the RRO 2005. Progress saved automatically.

2

Review findings & action plan

FRASafe generates a prioritised action plan with risk ratings for every finding. Review and sign your declarations before generating the report.

3

Download your PDF report

For £45, download your finished fire risk assessment PDF, laid out for your licence application.

Real reviews

What HMO landlords say

★★★★★
“I manage three HMOs. An assessor quoted £350 each, over £1,000. I did all three with FRASafe in an afternoon for £135.”
Neil B. · HMO landlord · Nottingham
★★★★★
“I was required to undergo a fire risk assessment as part of my HMO application. I found the Frasafe online form easy to complete and upload information to produce a Fire Risk Assessment that was relevant to my property. The price point of £45 was affordable, making Frasafe the right choice for my needs as a busy Landlord.”
Karin Tong · Trustpilot review
★★★★★
“Super smooth process for getting my fire safety report for my AirBNB property. Will be using again.”
John Harrington · Trustpilot review

Free tool

How fire-safe is your HMO?

Take the free 60-second fire safety check and get an instant Red, Amber or Green score, plus the things to fix first. No obligation.

Take the free check

Simple pricing

No subscription. No hidden fees. Pay once per report.

Fire Risk Assessment

£200–£500 professional assessor

£45
  • Full BS 9792:2025 questionnaire
  • Works offline on-site
  • PDF fire risk assessment in your name
  • Built on the LACORS fire safety guide
  • Lifetime access to your report
  • Annual review reminder
Get my fire risk assessment →

One-off payment, taken securely at checkout.

Rejected report? Full refund.

If your council rejects your FRASafe report because of its format or the standard it is written to, send us their reason in writing within 30 days and we will refund your £45 in full. You take no risk. This does not apply if you went ahead after we told you your council requires a qualified assessor.

Common questions

How do I get an HMO fire risk assessment done in St Albans?
You can pay an on-site fire risk assessor, or do it yourself online with FRASafe for £45. The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.
Does St Albans want to see my fire risk assessment?
The council lists a written fire risk assessment as one of the documents you send with your HMO licence application.
What will my St Albans fire risk assessment check?
For a typical 3-storey shared house with 6 tenants, St Albans's rules ask for: a linked fire alarm system (Grade A, LD2, plus a linked smoke alarm in each letting); fire doors with self-closers on every bedroom and the kitchen; a protected escape route, with the hall and stairs giving 30 minutes' fire resistance; a linked heat detector in the kitchen; emergency lighting on the escape route. Anything your house is missing goes into your action plan with a priority and the rule it comes from.

Start your St Albans HMO fire risk assessment today

£45 for your PDF report. No subscription.