Skip to main content

HMO fire risk assessment

Fire risk assessments for Ripon HMOs.

Every Ripon HMO needs a written fire risk assessment. Do yours online to BS 9792:2025, and see what North Yorkshire's own fire safety rules mean for your house.

Skip the £200–£500 assessor bill. Built on the guidance councils use, for £45.

BS 9792:2025 methodBuilt on the LACORS guideWorks offline on-siteInstant PDF report

Refund guarantee: full refund if your council rejects our report’s format or the standard it’s written to. Terms apply.

£45 one-off · PDF report · no subscription

RiponNorth Yorkshire council area
Council rulesOwn standard, June 2018
Typical assessor cost£200–£500
With FRASafe£45
TurnaroundSame day

Written by Bradley, Founder of FRASafeCouncil rules last checked 1 October 2026How we check →

Yorkshire and The Humber

North Yorkshire's HMO fire safety rules

North Yorkshire publishes its own HMO fire safety standard, "Fire Safety Guidance for Houses in Multiple Occupation (North Yorkshire)" (June 2018). It is based on the North Yorkshire standard, which 1 other council uses too. FRASafe's assessment follows BS 9792:2025 and LACORS. Below is what North Yorkshire's rules ask for in a typical house, so you know what to expect.

Assessment for the licence
Yes, with your licence application
Who can carry it out
No rule on who writes it
Last checked
1 October 2026

Worked example

What your Ripon fire risk assessment will check

A typical 3-storey shared house with 6 tenants, run through North Yorkshire's rules. Each item shows the wording it comes from, and what your action plan says if the house is missing it. Your own house may need more or less, which is what the assessment works out.

Fire alarm

Required

A linked fire alarm system (Grade D2, LD3)

“interlinked hard-wired smoke detectors (heat detector to kitchen) with integral battery back up within the staircase enclosure, rooms accessed from the staircase enclosure (with the exception of the bathroom/WC) (Include all bedrooms, living rooms, dining rooms and cellar ... Automatic Fire Detection and alarm system throughout the building (staircase enclosure and lobbies and rooms leading off the staircase enclosure) ... Grade A system in accordance with British Standard 5839: Part 1”
Fire Safety Guidance for Houses in Multiple Occupation (North Yorkshire FRS and the North Yorkshire authorities, hosted by North Yorkshire Council), June 2018

If it's missing: High priority in your action plan

The fire alarm is Grade F. This house needs a Grade D2 system with LD3 coverage. Have a qualified alarm engineer upgrade it to BS 5839-6. Required by LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing (July 2008).

Fire doors

Required

Fire doors with self-closers on every bedroom and the kitchen

“Fire doors to all rooms leading onto a means of escape (with the exception of bathrooms/WC) ... Fire doors to all rooms that can be accessed from the staircase, (with the exception of the bathroom/WC) ... fire resistant doors to all rooms leading onto a means of escape (with the exception of bathrooms/WC), including fire doorsets to British Standard 8214”
Fire Safety Guidance for Houses in Multiple Occupation (North Yorkshire FRS and the North Yorkshire authorities, hosted by North Yorkshire Council), June 2018

If it's missing: High priority in your action plan

Not every bedroom door is a fire door with a self-closer. Fit FD30 fire doors with self-closers to all bedrooms. Required by Fire Safety Guidance for Houses in Multiple Occupation (North Yorkshire FRS and the North Yorkshire authorities, hosted by North Yorkshire Council) (June 2018).

Escape route

Required

A protected escape route, with the hall and stairs giving 30 minutes' fire resistance

“Walls to the ground floor kitchen and to the staircase enclosure to be ... 30 minute protected route including wall and ceiling constructions to risk rooms ... A protected escape route should be provided”
Fire Safety Guidance for Houses in Multiple Occupation (North Yorkshire FRS and the North Yorkshire authorities, hosted by North Yorkshire Council), June 2018

If it's missing: High priority in your action plan

The hallway and stairs are not confirmed as a 30-minute protected route. Make good any holes or open-plan gaps so walls and ceilings give 30 minutes' fire resistance. Required by Fire Safety Guidance for Houses in Multiple Occupation (North Yorkshire FRS and the North Yorkshire authorities, hosted by North Yorkshire Council) (June 2018).

Kitchen heat detector

Required

A linked heat detector in the kitchen

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

If it's missing: High priority in your action plan

Not every kitchen has a linked heat alarm. Fit an interlinked heat alarm in each kitchen. Required by LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing (July 2008).

Emergency lighting

Not needed here

Not needed in this example house

“Emergency escape lighting required only if the route is long or complex or where there is no effective borrowed light ... Shared house HMO of five or six storeys (shared cooking facilities) Conventional lighting and emergency escape lighting”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Spotted something out of date? Tell us and we will check it.

How it works

From Blank Screen to Finished Report in 35 Minutes

Produce a BS 9792:2025 HMO fire risk assessment, checked against the LACORS housing fire safety guide that most councils use.

You do not need to be a fire-safety expert. FRASafe turns the legal requirements into plain-English questions and builds the report for you.

1

Complete the assessment

Answer structured questions covering fire hazards, means of escape, fire detection, fire doors, and more, mapped to BS 9792:2025 and the RRO 2005. Progress saved automatically.

2

Review findings & action plan

FRASafe generates a prioritised action plan with risk ratings for every finding. Review and sign your declarations before generating the report.

3

Download your PDF report

For £45, download your finished fire risk assessment PDF, laid out for your licence application.

Real reviews

What HMO landlords say

★★★★★
“I manage three HMOs. An assessor quoted £350 each, over £1,000. I did all three with FRASafe in an afternoon for £135.”
Neil B. · HMO landlord · Nottingham
★★★★★
“I was required to undergo a fire risk assessment as part of my HMO application. I found the Frasafe online form easy to complete and upload information to produce a Fire Risk Assessment that was relevant to my property. The price point of £45 was affordable, making Frasafe the right choice for my needs as a busy Landlord.”
Karin Tong · Trustpilot review
★★★★★
“Super smooth process for getting my fire safety report for my AirBNB property. Will be using again.”
John Harrington · Trustpilot review

Free tool

How fire-safe is your HMO?

Take the free 60-second fire safety check and get an instant Red, Amber or Green score, plus the things to fix first. No obligation.

Take the free check

Simple pricing

No subscription. No hidden fees. Pay once per report.

Fire Risk Assessment

£200–£500 professional assessor

£45
  • Full BS 9792:2025 questionnaire
  • Works offline on-site
  • PDF fire risk assessment in your name
  • Built on the LACORS fire safety guide
  • Lifetime access to your report
  • Annual review reminder
Get my fire risk assessment →

One-off payment, taken securely at checkout.

Rejected report? Full refund.

If your council rejects your FRASafe report because of its format or the standard it is written to, send us their reason in writing within 30 days and we will refund your £45 in full. You take no risk. This does not apply if you went ahead after we told you your council requires a qualified assessor.

Common questions

How do I get an HMO fire risk assessment done in Ripon?
You can pay an on-site fire risk assessor, or do it yourself online with FRASafe for £45. The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.
Does North Yorkshire want to see my fire risk assessment?
The council lists a written fire risk assessment as one of the documents you send with your HMO licence application.
What will my Ripon fire risk assessment check?
For a typical 3-storey shared house with 6 tenants, North Yorkshire's rules ask for: a linked fire alarm system (Grade D2, LD3); fire doors with self-closers on every bedroom and the kitchen; a protected escape route, with the hall and stairs giving 30 minutes' fire resistance; a linked heat detector in the kitchen. Anything your house is missing goes into your action plan with a priority and the rule it comes from.

Start your Ripon HMO fire risk assessment today

£45 for your PDF report. No subscription.