Every Nottingham HMO needs a written fire risk assessment. Do yours online to BS 9792:2025, and see what Nottingham's own fire safety rules mean for your house.

Skip the £200–£500 assessor bill. Built on the guidance councils use, for £45.

BS 9792:2025 methodBuilt on the LACORS guideWorks offline on-siteInstant PDF report

Refund guarantee: full refund if your council rejects our report’s format or the standard it’s written to. Terms apply.

£45 one-off · PDF report · no subscription

NottinghamNottingham council area
Council rulesOwn standard, Revised June 2024
Typical assessor cost£200–£500
With FRASafe£45
TurnaroundSame day

Written by Bradley, Founder of FRASafeCouncil rules last checked 12 October 2026How we check →

East Midlands

Nottingham's HMO fire safety rules

Nottingham publishes its own HMO fire safety standard, "Licence Conditions for Houses in Multiple Occupation (HMO)" (Revised June 2024). FRASafe's assessment follows BS 9792:2025 and LACORS. Below is what Nottingham's rules ask for in a typical house, so you know what to expect.

Assessment for the licence
Yes, with your licence application
Who can carry it out
No rule on who writes it
Last checked
12 October 2026

Running an HMO in Nottingham

The local rules and contacts that sit alongside your fire risk assessment, each taken from the council's or fire service's own website.

Fire and rescue service

Nottinghamshire Fire and Rescue Service covers Nottingham.

Source: notts-fire.gov.uk
Additional licensing

Nottingham runs additional licensing in the whole city, from 1st January 2024 to 31st December 2028, so smaller HMOs there need a licence too, not only those big enough for a mandatory licence.

Show the official wording
“The designation shall come into force on the 1st January 2024 and shall cease to have effect on the 31st December 2028.”
Source: nottinghamcity.gov.uk
Selective licensing

Nottingham runs selective licensing in a designated area covering over 30,000 privately rented homes (not the whole city), from 01 December 2023 to 30 November 2028, so most privately rented homes there need a licence, not just HMOs.

Show the official wording
“This designation is made on 17 January 2023 and shall come into force on 01 December 2023*. 3. This designation shall cease to have effect on 30 November 2028*.”
Source: nottinghamcity.gov.uk
Planning

Turning a family home into a small HMO needs planning permission in the whole city (an Article 4 direction, in force since 11th March 2012).

Show the official wording
“Changes to local planning rules mean that from 11th March 2012 it will generally be necessary to obtain planning permission for changes of use from existing family/single occupancy dwellings to small HMOs with between 3 and 6 unrelated persons throughout the City of Nottingham.”
Source: nottinghamcity.gov.uk
Licence fee

A new HMO licence from Nottingham costs £1,607 for up to 9 bedrooms (£697 on application, £910 later); £1,210 for accredited landlords (from 1 April 2026).

Show the official wording
“Standard, For non-accredited landlords Application fee up to 9 bedrooms 1st Payment (Part A): £697 2nd Payment (Part B): £910 Total: £1607”
Source: nottinghamcity.gov.uk
Licensed HMOs

3,414 HMOs on Nottingham's licence register (1 October 2026).

Show the official wording
“HMO Register Of Licences - 1 October 2026”
Source: nottinghamcity.gov.uk

Applying for or renewing your Nottingham HMO licence? Nottingham wants a written fire risk assessment with your application.

Get my fire risk assessment

Worked example

What your Nottingham fire risk assessment will check

A typical 3-storey shared house with 6 tenants, run through Nottingham's rules. Each item shows the wording it comes from, and what your action plan says if the house is missing it. Your own house may need more or less, which is what the assessment works out.

Fire alarm

Required

A linked fire alarm system (Grade D2, LD3)

“Shared house HMO of three or four storeys (shared cooking facilities) Grade D: LD3 coverage + additional detection to the kitchen, lounge and any cellar containing a risk (interlinked) Shared house HMO of five or six storeys (shared cooking facilities) Grade A: LD2 coverage ... Bedsit HMO of one or two storeys with individual cooking facilities within bedsits A mixed system: Grade D: LD2 coverage in the common areas and heat detectors in bedsits (interlinked) Grade D smoke alarm in each bedsit to protect the sleeping occupants (non-interlinked) Bedsit HMO of three to six storeys with individual cooking facilities within bedsits A mixed system: Grade A: LD2 coverage in the common areas ... Where cooking facilities are sited in shared kitchen, not within bedsits: interlinked smoke alarms with integral battery backup located in each bedsit”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

If it's missing: High priority in your action plan

The fire alarm is Grade F. This house needs a Grade D2 system with LD3 coverage. Have a qualified alarm engineer upgrade it to BS 5839-6. Required by LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing (July 2008).

Fire doors

Required

Fire doors with self-closers on every bedroom and the kitchen

“30-minute protected route note 8, is required, including 30-minute fire-resisting construction and FD30 doors to all risk rooms (without smoke seals ... 30-minute fire-resisting construction and FD30S doors to all risk rooms. Travel distance must not be excessive”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

If it's missing: High priority in your action plan

Not every bedroom door is a fire door with a self-closer. Fit FD30 fire doors with self-closers to all bedrooms. Required by LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing (July 2008).

Escape route

Required

A protected escape route, with the hall and stairs giving 30 minutes' fire resistance

“No requirement for full 30-minute protected route note 7, but the escape route should have sound, traditional construction and should not pass through risk rooms ... 30-minute protected route note 8, is required, including 30-minute fire-resisting construction”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

If it's missing: High priority in your action plan

The hallway and stairs are not confirmed as a 30-minute protected route. Make good any holes or open-plan gaps so walls and ceilings give 30 minutes' fire resistance. Required by LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing (July 2008).

Kitchen heat detector

Required

A linked heat detector in the kitchen

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

If it's missing: High priority in your action plan

Not every kitchen has a linked heat alarm. Fit an interlinked heat alarm in each kitchen. Required by LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing (July 2008).

Emergency lighting

Not needed here

Not needed in this example house

“Emergency escape lighting required only if the route is long or complex or where there is no effective borrowed light ... Shared house HMO of five or six storeys (shared cooking facilities) Conventional lighting and emergency escape lighting”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Spotted something out of date? Tell us and we will check it.

How it works

From Blank Screen to Finished Report in 35 Minutes

Produce a BS 9792:2025 HMO fire risk assessment, checked against the LACORS housing fire safety guide that most councils use.

You do not need to be a fire-safety expert. FRASafe turns the legal requirements into plain-English questions and builds the report for you.

1

Complete the assessment

Answer structured questions covering fire hazards, means of escape, fire detection, fire doors, and more, mapped to BS 9792:2025 and the RRO 2005. Progress saved automatically.

2

Review findings & action plan

FRASafe generates a prioritised action plan with risk ratings for every finding. Review and sign your declarations before generating the report.

3

Download your PDF report

For £45, download your finished fire risk assessment PDF, laid out for your licence application.

Real reviews

What HMO landlords say

★★★★★
“I manage three HMOs. An assessor quoted £350 each, over £1,000. I did all three with FRASafe in an afternoon for £135.”
Neil B. · HMO landlord · Nottingham
★★★★★
“I was required to undergo a fire risk assessment as part of my HMO application. I found the Frasafe online form easy to complete and upload information to produce a Fire Risk Assessment that was relevant to my property. The price point of £45 was affordable, making Frasafe the right choice for my needs as a busy Landlord.”
Karin Tong · Trustpilot review
★★★★★
“Super smooth process for getting my fire safety report for my AirBNB property. Will be using again.”
John Harrington · Trustpilot review

Free tool

How fire-safe is your HMO?

Take the free 60-second fire safety check and get an instant Red, Amber or Green score, plus the things to fix first. No obligation.

Take the free check

Simple pricing

No subscription. No hidden fees. Pay once per report.

Fire Risk Assessment

£200–£500 professional assessor

£45
  • Full BS 9792:2025 questionnaire
  • Works offline on-site
  • PDF fire risk assessment in your name
  • Built on the LACORS fire safety guide
  • Lifetime access to your report
  • Annual review reminder
Get my fire risk assessment →

One-off payment, taken securely at checkout.

Rejected report? Full refund.

If your council rejects your FRASafe report because of its format or the standard it is written to, send us their reason in writing within 30 days and we will refund your £45 in full. You take no risk. This does not apply if you went ahead after we told you your council requires a qualified assessor.

Common questions

How do I get an HMO fire risk assessment done in Nottingham?
You can pay an on-site fire risk assessor, or do it yourself online with FRASafe for £45. The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.
Does Nottingham want to see my fire risk assessment?
The council lists a written fire risk assessment as one of the documents you send with your HMO licence application.
What will my Nottingham fire risk assessment check?
For a typical 3-storey shared house with 6 tenants, Nottingham's rules ask for: a linked fire alarm system (Grade D2, LD3); fire doors with self-closers on every bedroom and the kitchen; a protected escape route, with the hall and stairs giving 30 minutes' fire resistance; a linked heat detector in the kitchen. Anything your house is missing goes into your action plan with a priority and the rule it comes from.

Start your Nottingham HMO fire risk assessment today

£45 for your PDF report. No subscription.