Westminster HMO fire safety requirements

Westminster publishes its own HMO fire safety standard, "Guide to Houses in Multiple Occupation: Shared houses and flats standards (Westminster City Council)" (April 2021).

Is a fire risk assessment needed for the licence?

Expected, but not sent in

The council's guidance talks about fire risk assessments, but it does not ask you to send one with your application. Fire safety law still says you need one.

Who can carry it out?

No rule on who writes it

The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.

Which standard applies?

Guide to Houses in Multiple Occupation: Shared houses and flats standards (Westminster City Council)

Published April 2021.

Read the council's document →

When did we last check?

14 October 2026

We re-check every council's documents each month and update this page when they change.

What Westminster expects in 3 typical HMOs

Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.

2-storey shared house, 5 tenants

Fire alarm system
Grade D1, LD2
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended

3-storey shared house, 6 tenants

Fire alarm system
Grade A, LD2
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended

3-storey bedsits with cooking in rooms, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked heat detector and a standalone smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended
  • Grade D1 (mains alarms with a sealed backup battery)
  • Grade A (a panel system with call points)
  • LD2 (escape route plus rooms where fires are likely to start)

In the council's own words

The wording these requirements come from, quoted from the published documents.

Fire alarms

Council's own standard

“Grade D1 mains powered [with tamper proof battery backup] AFD system must be provided in houses up to 2 storeys. The system should provide Category LD2 coverage, with smoke alarms in the bedrooms, entrance hallway, any internal stairway, shared living room, together with a heat alarm in the kitchen.”
Guide to Houses in Multiple Occupation: Shared houses and flats standards (Westminster City Council), April 2021

Fire doors

Council's own standard

“The layout and design of the house must provide a protected escape route from the bedrooms to the front door. In most cases this is by means of a protected entrance hallway comprising fire resisting partitions and internal fire doors. Internal fire doors must provide at least 20 minutes fire resistance.”
Guide to Houses in Multiple Occupation: Shared houses and flats standards (Westminster City Council), April 2021

Escape route

Council's own standard

“The layout and design of the house must provide a protected escape route from the bedrooms to the front door. In most cases this is by means of a protected entrance hallway comprising fire resisting partitions and internal fire doors. Internal fire doors must provide at least 20 minutes fire resistance.”
Guide to Houses in Multiple Occupation: Shared houses and flats standards (Westminster City Council), April 2021

Kitchen heat detector

LACORS national guide

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Emergency lighting

Council's own standard

“Emergency lighting which comes on if mains electricity fails must be fitted to illuminate the protected route and some internal staircases, and must be in compliance with BS 5266.”
Guide to Houses in Multiple Occupation: Bedsit and studio standards (Westminster City Council), April 2021

Fire extinguishers

Council's own standard

“A 1 litre multi-purpose extinguisher suitable for use on electrical fires should be sited in the kitchen or hallway.”
Guide to Houses in Multiple Occupation: Shared houses and flats standards (Westminster City Council), April 2021

Spotted something out of date? Tell us and we will check it.

Common questions

Do I need a fire risk assessment for a Westminster HMO licence?
The council's guidance talks about fire risk assessments, but it does not ask you to send one with your application. Fire safety law still says you need one.
Can I do my own HMO fire risk assessment in Westminster?
The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.
Which fire safety standard does Westminster use for HMOs?
Westminster publishes "Guide to Houses in Multiple Occupation: Shared houses and flats standards (Westminster City Council)" (April 2021). Like most councils, it builds on the national LACORS guide.
What fire alarm does a 3-storey shared house need in Westminster?
For a typical 3-storey shared house with 6 tenants, Westminster's rules work out at Grade A, LD2. Your house may need something different depending on its layout, so check it properly with a fire risk assessment.

Check your Westminster HMO against the council's standard