Skip to main content
£45 one-off •Your fire risk assessment in 35 minutes •No subscription

East of England

Welwyn Hatfield HMO fire safety requirements

Welwyn Hatfield publishes its own HMO fire safety standard, "HMO Standards (Welwyn Hatfield HMO Amenity Standards), section 5 Fire Precautionary Facilities" (December 2019). It is based on the Hertfordshire standard, which 3 other councils use too.

Is a fire risk assessment needed for the licence?

Not stated by the council

We could not find the council saying whether it wants to see your fire risk assessment. Fire safety law still says the landlord of an HMO must have one.

Who can carry it out?

No rule on who writes it

The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.

Which standard applies?

HMO Standards (Welwyn Hatfield HMO Amenity Standards), section 5 Fire Precautionary Facilities

Published December 2019.

Read the council's document →

When did we last check?

29 September 2026

We re-check every council's documents each month and update this page when they change.

What Welwyn Hatfield expects in 3 typical HMOs

Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.

2-storey shared house, 5 tenants

Fire alarm system
Grade D1, LD2, plus a linked smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Required
Fire blanket in the kitchen
Required
Fire extinguishers
Not advised

3-storey shared house, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Required
Fire blanket in the kitchen
Required
Fire extinguishers
Not advised

3-storey bedsits with cooking in rooms, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked heat detector and a standalone smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Required
Fire blanket in the kitchen
Required
Fire extinguishers
Not advised
  • Grade D1 (mains alarms with a sealed backup battery)
  • Grade A (a panel system with call points)
  • LD2 (escape route plus rooms where fires are likely to start)

In the council's own words

The wording these requirements come from, quoted from the published documents.

Fire alarms

Shared regional standard

“All HMOs must have automatic fire alarm systems installed. The requirements are different for two storey HMOs and for three (or more) storey HMOs ... Provide a Fire Alarm System to include smoke detectors in every bedroom, throughout the escape route and in communal living rooms ... The detectors must be hard wired to the mains and interlinked with integral battery back-up. The system must comply with the current British Standard 5839 part 6: Grade D1, LD2 (or equivalent) ... interlinked with a control panel containing battery back-up. The system must comply with the current British Standard 5839 part 6: Grade A LD2 (or equivalent).”
SADC HMO Amenity Standards (St Albans City and District Council), 2019

Fire doors

Shared regional standard

“Ensure that there are self-closing fire doors that provide 30 minutes fire and smoke protection (FD30S) on all bedrooms, kitchens and living rooms.”
SADC HMO Amenity Standards (St Albans City and District Council), 2019

Escape route

Shared regional standard

“All HMOs shall be provided with an adequate protected means of escape from fire, together with other fire precautions including so far as necessary, a fire detection and warning system with emergency lighting to the satisfaction of the inspecting officer.”
SADC HMO Amenity Standards (St Albans City and District Council), 2019

Kitchen heat detector

LACORS national guide

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Emergency lighting

Shared regional standard

“Arrange for the installation of suitable and sufficient emergency lighting to provide adequate coverage to the protected fire escape route. The number and position of any luminaries should be determined by your fire risk assessment.”
SADC HMO Amenity Standards (St Albans City and District Council), 2019

Fire extinguishers

Shared regional standard

“The use of fire extinguishers is not recommended in HMOs, however if they are provided they must be: a) Checked and serviced annually with records kept.”
SADC HMO Amenity Standards (St Albans City and District Council), 2019

Spotted something out of date? Tell us and we will check it.

Not in Welwyn Hatfield?

Councils using the same standard as Welwyn Hatfield

Common questions

Do I need a fire risk assessment for a Welwyn Hatfield HMO licence?
We could not find the council saying whether it wants to see your fire risk assessment. Fire safety law still says the landlord of an HMO must have one.
Can I do my own HMO fire risk assessment in Welwyn Hatfield?
The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.
Which fire safety standard does Welwyn Hatfield use for HMOs?
Welwyn Hatfield publishes "HMO Standards (Welwyn Hatfield HMO Amenity Standards), section 5 Fire Precautionary Facilities" (December 2019).
What fire alarm does a 3-storey shared house need in Welwyn Hatfield?
For a typical 3-storey shared house with 6 tenants, Welwyn Hatfield's rules work out at Grade A, LD2, plus a linked smoke alarm in each letting. Your house may need something different depending on its layout, so check it properly with a fire risk assessment.

Check your Welwyn Hatfield HMO against the council's standard

Answer plain-English questions about your house and get a fire risk assessment report built on Welwyn Hatfield's rules. £45, no subscription.