Swansea HMO fire safety requirements

Swansea publishes its own HMO fire safety standard, "HMO Licensing Policy 2020, Appendix B Means of Escape: Housing Fire Safety Quick Reference Guide (Wales)" (2020). It is based on the Wales standard, which 2 other councils use too.

Is a fire risk assessment needed for the licence?

Not stated by the council

We could not find the council saying whether it wants to see your fire risk assessment. Fire safety law still says the landlord of an HMO must have one.

Who can carry it out?

No rule on who writes it

The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.

Which standard applies?

HMO Licensing Policy 2020, Appendix B Means of Escape: Housing Fire Safety Quick Reference Guide (Wales)

Published 2020.

Read the council's document →

When did we last check?

4 October 2026

We re-check every council's documents each month and update this page when they change.

What Swansea expects in 3 typical HMOs

Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.

2-storey shared house, 5 tenants

Fire alarm system
Grade D2, LD3
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended

3-storey shared house, 6 tenants

Fire alarm system
Grade D2, LD3
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended

3-storey bedsits with cooking in rooms, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked heat detector and a standalone smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Required
  • Grade D2 (mains alarms with a replaceable backup battery)
  • Grade A (a panel system with call points)
  • LD3 (escape route only)
  • LD2 (escape route plus rooms where fires are likely to start)

In the council's own words

The wording these requirements come from, quoted from the published documents.

Fire alarms

LACORS national guide

“Shared house HMO of three or four storeys (shared cooking facilities) Grade D: LD3 coverage + additional detection to the kitchen, lounge and any cellar containing a risk (interlinked) Shared house HMO of five or six storeys (shared cooking facilities) Grade A: LD2 coverage ... Bedsit HMO of one or two storeys with individual cooking facilities within bedsits A mixed system: Grade D: LD2 coverage in the common areas and heat detectors in bedsits (interlinked) Grade D smoke alarm in each bedsit to protect the sleeping occupants (non-interlinked) Bedsit HMO of three to six storeys with individual cooking facilities within bedsits A mixed system: Grade A: LD2 coverage in the common areas ... Where cooking facilities are sited in shared kitchen, not within bedsits: interlinked smoke alarms with integral battery backup located in each bedsit”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Fire doors

Shared regional standard

“Ideal standard (for normal risk property) ... 30 minute protected route with FD30 Fire Doors (no smoke seals) ... In low risk shared houses (see below)”
Housing Fire Safety: Quick Reference Guide (Wales), Housing Technical Panel (Caerphilly copy), Undated

Escape route

Shared regional standard

“Ideal standard (for normal risk property) ... 30 minute protected route with FD30 Fire Doors (no smoke seals) ... In low risk shared houses (see below)”
Housing Fire Safety: Quick Reference Guide (Wales), Housing Technical Panel (Caerphilly copy), Undated

Kitchen heat detector

LACORS national guide

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Emergency lighting

LACORS national guide

“Emergency escape lighting required only if the route is long or complex or where there is no effective borrowed light ... Shared house HMO of five or six storeys (shared cooking facilities) Conventional lighting and emergency escape lighting”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Fire extinguishers

Shared regional standard

“In shared houses, a multi-purpose fire extinguisher (type 1.5kg dry powder or 6 litre AFFF Foam) is recommended on each floor within the escape route. In all HMOs where the Fire Safety Order applies, including houses converted to self contained flats and bedsits, multi-purpose extinguishers (type as above) are required unless the landlord can demonstrate through risk assessment that an acceptable level of safety can be achieved without the provision of extinguishers.”
Housing Fire Safety: Quick Reference Guide (Wales), Housing Technical Panel (Caerphilly copy), Undated

Spotted something out of date? Tell us and we will check it.

Common questions

Do I need a fire risk assessment for a Swansea HMO licence?
We could not find the council saying whether it wants to see your fire risk assessment. Fire safety law still says the landlord of an HMO must have one.
Can I do my own HMO fire risk assessment in Swansea?
The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.
Which fire safety standard does Swansea use for HMOs?
Swansea publishes "HMO Licensing Policy 2020, Appendix B Means of Escape: Housing Fire Safety Quick Reference Guide (Wales)" (2020).
What fire alarm does a 3-storey shared house need in Swansea?
For a typical 3-storey shared house with 6 tenants, Swansea's rules work out at Grade D2, LD3. Your house may need something different depending on its layout, so check it properly with a fire risk assessment.

Check your Swansea HMO against the council's standard