St Helens HMO fire safety requirements

St Helens publishes its own HMO fire safety standard, "HMO Information Sheet 1: Bedsits/Shared Houses" (Undated (file dated 2022, cites BS 5839-6:2004)).

Is a fire risk assessment needed for the licence?

Not stated by the council

We could not find the council saying whether it wants to see your fire risk assessment. Fire safety law still says the landlord of an HMO must have one.

Who can carry it out?

No rule on who writes it

The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.

Which standard applies?

HMO Information Sheet 1: Bedsits/Shared Houses

Published Undated (file dated 2022, cites BS 5839-6:2004).

Read the council's document →

When did we last check?

15 October 2026

We re-check every council's documents each month and update this page when they change.

What St Helens expects in 3 typical HMOs

Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.

2-storey shared house, 5 tenants

Fire alarm system
Grade D2, LD3
Fire doors on bedrooms
Not required
Fire door on the kitchen
Not required
Protected escape route
Not required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended

3-storey shared house, 6 tenants

Fire alarm system
Grade D2, LD3
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended

3-storey bedsits with cooking in rooms, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked heat detector and a standalone smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended
  • Grade D2 (mains alarms with a replaceable backup battery)
  • Grade A (a panel system with call points)
  • LD3 (escape route only)
  • LD2 (escape route plus rooms where fires are likely to start)

In the council's own words

The wording these requirements come from, quoted from the published documents.

Fire alarms

Council's own standard

“consideration will be given to Lacors fire safety guidance, which states: All HMOs of three storeys or more should have a panel controlled automatic fire alarm and detection system covering all parts of the premises, that is rooms, halls and stairs, kitchens etc. All HMOs of two storeys should have a simpler system, but it should cover the same areas, all rooms, halls and stairs and kitchens.”
Regulatory Reform (Fire Safety) Order 2005 (St Helens Borough Council web page), Accessed October 2026

Fire doors

LACORS national guide

“30-minute protected route note 8, is required, including 30-minute fire-resisting construction and FD30 doors to all risk rooms (without smoke seals ... 30-minute fire-resisting construction and FD30S doors to all risk rooms. Travel distance must not be excessive”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Escape route

LACORS national guide

“No requirement for full 30-minute protected route note 7, but the escape route should have sound, traditional construction and should not pass through risk rooms ... 30-minute protected route note 8, is required, including 30-minute fire-resisting construction”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Kitchen heat detector

LACORS national guide

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Emergency lighting

Council's own standard

“This advice sheet gives brief details of the council’s standards for means of escape in case of fire and other fire precautions within a licensable property of 3 or more storeys. ... A non-maintained Emergency Lighting system conforming to BS5266 Part 1:1999”
HMO Information Sheet 1: Bedsits/Shared Houses (St Helens Borough Council), Undated

Fire extinguishers

LACORS national guide

“a simple multi-purpose extinguisher is recommended on each floor in the common parts of HMOs and buildings containing flats.”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Spotted something out of date? Tell us and we will check it.

Common questions

Do I need a fire risk assessment for a St Helens HMO licence?
We could not find the council saying whether it wants to see your fire risk assessment. Fire safety law still says the landlord of an HMO must have one.
Can I do my own HMO fire risk assessment in St Helens?
The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.
Which fire safety standard does St Helens use for HMOs?
St Helens publishes "HMO Information Sheet 1: Bedsits/Shared Houses" (Undated (file dated 2022, cites BS 5839-6:2004)). Like most councils, it builds on the national LACORS guide.
What fire alarm does a 3-storey shared house need in St Helens?
For a typical 3-storey shared house with 6 tenants, St Helens's rules work out at Grade D2, LD3. Your house may need something different depending on its layout, so check it properly with a fire risk assessment.

Check your St Helens HMO against the council's standard

Answer plain-English questions about your house and get a fire risk assessment report built on St Helens's rules. £45, no subscription.