St Helens HMO fire safety requirements
St Helens publishes its own HMO fire safety standard, "HMO Information Sheet 1: Bedsits/Shared Houses" (Undated (file dated 2022, cites BS 5839-6:2004)).
Is a fire risk assessment needed for the licence?
Not stated by the council
We could not find the council saying whether it wants to see your fire risk assessment. Fire safety law still says the landlord of an HMO must have one.
Who can carry it out?
No rule on who writes it
The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.
Which standard applies?
HMO Information Sheet 1: Bedsits/Shared Houses
Published Undated (file dated 2022, cites BS 5839-6:2004).
Read the council's document →When did we last check?
15 October 2026
We re-check every council's documents each month and update this page when they change.
What St Helens expects in 3 typical HMOs
Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.
2-storey shared house, 5 tenants
- Fire alarm system
- Grade D2, LD3
- Fire doors on bedrooms
- Not required
- Fire door on the kitchen
- Not required
- Protected escape route
- Not required
- Heat detector in the kitchen
- Required
- Emergency lighting
- Not required
- Fire blanket in the kitchen
- Required
- Fire extinguishers
- Recommended
3-storey shared house, 6 tenants
- Fire alarm system
- Grade D2, LD3
- Fire doors on bedrooms
- Required
- Fire door on the kitchen
- Required
- Protected escape route
- Required
- Heat detector in the kitchen
- Required
- Emergency lighting
- Required
- Fire blanket in the kitchen
- Required
- Fire extinguishers
- Recommended
3-storey bedsits with cooking in rooms, 6 tenants
- Fire alarm system
- Grade A, LD2, plus a linked heat detector and a standalone smoke alarm in each letting
- Fire doors on bedrooms
- Required
- Fire door on the kitchen
- Required
- Protected escape route
- Required
- Heat detector in the kitchen
- Required
- Emergency lighting
- Required
- Fire blanket in the kitchen
- Required
- Fire extinguishers
- Recommended
| Requirement | 2-storey shared house, 5 tenants | 3-storey shared house, 6 tenants | 3-storey bedsits with cooking in rooms, 6 tenants |
|---|---|---|---|
| Fire alarm system | Grade D2, LD3 | Grade D2, LD3 | Grade A, LD2, plus a linked heat detector and a standalone smoke alarm in each letting |
| Fire doors on bedrooms | Not required | Required | Required |
| Fire door on the kitchen | Not required | Required | Required |
| Protected escape route | Not required | Required | Required |
| Heat detector in the kitchen | Required | Required | Required |
| Emergency lighting | Not required | Required | Required |
| Fire blanket in the kitchen | Required | Required | Required |
| Fire extinguishers | Recommended | Recommended | Recommended |
- Grade D2 (mains alarms with a replaceable backup battery)
- Grade A (a panel system with call points)
- LD3 (escape route only)
- LD2 (escape route plus rooms where fires are likely to start)
In the council's own words
The wording these requirements come from, quoted from the published documents.
Fire alarms
Council's own standard
“consideration will be given to Lacors fire safety guidance, which states: All HMOs of three storeys or more should have a panel controlled automatic fire alarm and detection system covering all parts of the premises, that is rooms, halls and stairs, kitchens etc. All HMOs of two storeys should have a simpler system, but it should cover the same areas, all rooms, halls and stairs and kitchens.”
Fire doors
LACORS national guide
“30-minute protected route note 8, is required, including 30-minute fire-resisting construction and FD30 doors to all risk rooms (without smoke seals ... 30-minute fire-resisting construction and FD30S doors to all risk rooms. Travel distance must not be excessive”
Escape route
LACORS national guide
“No requirement for full 30-minute protected route note 7, but the escape route should have sound, traditional construction and should not pass through risk rooms ... 30-minute protected route note 8, is required, including 30-minute fire-resisting construction”
Kitchen heat detector
LACORS national guide
“additional interlinked heat alarm with integral battery back-up located in the kitchen”
Emergency lighting
Council's own standard
“This advice sheet gives brief details of the council’s standards for means of escape in case of fire and other fire precautions within a licensable property of 3 or more storeys. ... A non-maintained Emergency Lighting system conforming to BS5266 Part 1:1999”
Fire extinguishers
LACORS national guide
“a simple multi-purpose extinguisher is recommended on each floor in the common parts of HMOs and buildings containing flats.”
Spotted something out of date? Tell us and we will check it.
Common questions
Do I need a fire risk assessment for a St Helens HMO licence?
Can I do my own HMO fire risk assessment in St Helens?
Which fire safety standard does St Helens use for HMOs?
What fire alarm does a 3-storey shared house need in St Helens?
Check your St Helens HMO against the council's standard
Answer plain-English questions about your house and get a fire risk assessment report built on St Helens's rules. £45, no subscription.