South Tyneside HMO fire safety requirements

South Tyneside publishes its own HMO fire safety standard, "Landlords' Guide to Standards for Houses in Multiple Occupation (South Tyneside Council)" (Undated (2025)).

Is a fire risk assessment needed for the licence?

Yes, with your licence application

The council lists a written fire risk assessment as one of the documents you send with your HMO licence application.

Who can carry it out?

A "competent person"

The council says a "competent person" must carry it out. In fire safety law that means someone with enough training, experience or knowledge to assess the house properly. A careful landlord can meet that.

Which standard applies?

Landlords' Guide to Standards for Houses in Multiple Occupation (South Tyneside Council)

Published Undated (2025).

Read the council's document →

When did we last check?

15 October 2026

We re-check every council's documents each month and update this page when they change.

What South Tyneside expects in 3 typical HMOs

Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.

2-storey shared house, 5 tenants

Fire alarm system
Grade D1, LD3
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended

3-storey shared house, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended

3-storey bedsits with cooking in rooms, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked heat detector and a standalone smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended
  • Grade D1 (mains alarms with a sealed backup battery)
  • Grade A (a panel system with call points)
  • LD3 (escape route only)
  • LD2 (escape route plus rooms where fires are likely to start)

In the council's own words

The wording these requirements come from, quoted from the published documents.

Fire alarms

Council's own standard

“The detectors to be installed in escape route at all levels, in shared lounge and heat detector in shared kitchen(s) ... detectors to be installed in escape routes at all levels, in all bedrooms, lounge, dining room and any other high risk rooms, linked to a control panel with manual call points”
Landlords' Guide to Standards for Houses in Multiple Occupation (South Tyneside Council), Undated (2025)

Fire doors

Council's own standard

“In most cases, fire doors are required to be fitted to bedrooms”
Landlords' Guide to Standards for Houses in Multiple Occupation (South Tyneside Council), Undated (2025)

Escape route

Council's own standard

“Fire resisting materials must be on each part of the building on the protected route, which is the walls”
Landlords' Guide to Standards for Houses in Multiple Occupation (South Tyneside Council), Undated (2025)

Kitchen heat detector

LACORS national guide

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Emergency lighting

Council's own standard

“Emergency escape lighting is required if the route is”
Landlords' Guide to Standards for Houses in Multiple Occupation (South Tyneside Council), Undated (2025)

Fire extinguishers

LACORS national guide

“a simple multi-purpose extinguisher is recommended on each floor in the common parts of HMOs and buildings containing flats.”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Spotted something out of date? Tell us and we will check it.

Common questions

Do I need a fire risk assessment for a South Tyneside HMO licence?
The council lists a written fire risk assessment as one of the documents you send with your HMO licence application.
Can I do my own HMO fire risk assessment in South Tyneside?
The council says a "competent person" must carry it out. In fire safety law that means someone with enough training, experience or knowledge to assess the house properly. A careful landlord can meet that.
Which fire safety standard does South Tyneside use for HMOs?
South Tyneside publishes "Landlords' Guide to Standards for Houses in Multiple Occupation (South Tyneside Council)" (Undated (2025)). Like most councils, it builds on the national LACORS guide.
What fire alarm does a 3-storey shared house need in South Tyneside?
For a typical 3-storey shared house with 6 tenants, South Tyneside's rules work out at Grade A, LD2, plus a linked smoke alarm in each letting. Your house may need something different depending on its layout, so check it properly with a fire risk assessment.

Check your South Tyneside HMO against the council's standard

Answer plain-English questions about your house and get a fire risk assessment report built on South Tyneside's rules. £45, no subscription.