South Kesteven HMO fire safety requirements

South Kesteven publishes its own HMO fire safety standard, "Prescribed Standards for deciding the suitability for occupation of a House of Multiple Occupation (South Kesteven District Council)" (June 2021).

Is a fire risk assessment needed for the licence?

Not stated by the council

We could not find the council saying whether it wants to see your fire risk assessment. Fire safety law still says the landlord of an HMO must have one.

Who can carry it out?

A "competent person"

The council says a "competent person" must carry it out. In fire safety law that means someone with enough training, experience or knowledge to assess the house properly. A careful landlord can meet that.

Which standard applies?

Prescribed Standards for deciding the suitability for occupation of a House of Multiple Occupation (South Kesteven District Council)

Published June 2021.

Read the council's document →

When did we last check?

12 October 2026

We re-check every council's documents each month and update this page when they change.

What South Kesteven expects in 3 typical HMOs

Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.

2-storey shared house, 5 tenants

Fire alarm system
Grade D2, LD3
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Not required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended

3-storey shared house, 6 tenants

Fire alarm system
Grade A, LD2
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended

3-storey bedsits with cooking in rooms, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked heat detector and a standalone smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended
  • Grade D2 (mains alarms with a replaceable backup battery)
  • Grade A (a panel system with call points)
  • LD3 (escape route only)
  • LD2 (escape route plus rooms where fires are likely to start)

In the council's own words

The wording these requirements come from, quoted from the published documents.

Fire alarms

Council's own standard

“3 story or more, 5 person or more) ... mains wired panel controlled detection alarm system to (BS 5839 Part 1 2002) interconnected smoke detectors to be fitted to every bedroom and common hallway with heat detectors to kitchens and any cellar/ basement.”
Prescribed Standards for deciding the suitability for occupation of a House of Multiple Occupation (South Kesteven District Council), June 2021

Fire doors

Council's own standard

“All doors opening onto an escape route ... must be FD30S with the appropriate door furniture including a self-closing device, three hinges and intumescent strips. These must close fully without assistance. ... Not required in some instances of smaller shared houses.”
Prescribed Standards for deciding the suitability for occupation of a House of Multiple Occupation (South Kesteven District Council), June 2021

Escape route

LACORS national guide

“No requirement for full 30-minute protected route note 7, but the escape route should have sound, traditional construction and should not pass through risk rooms ... 30-minute protected route note 8, is required, including 30-minute fire-resisting construction”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Kitchen heat detector

LACORS national guide

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Emergency lighting

Council's own standard

“Emergency lighting to be fitted through the escape route in 3 story or larger properties or where there and complex escape routes, or where there is little or ineffective borrowed light.”
Prescribed Standards for deciding the suitability for occupation of a House of Multiple Occupation (South Kesteven District Council), June 2021

Fire extinguishers

LACORS national guide

“a simple multi-purpose extinguisher is recommended on each floor in the common parts of HMOs and buildings containing flats.”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Spotted something out of date? Tell us and we will check it.

Common questions

Do I need a fire risk assessment for a South Kesteven HMO licence?
We could not find the council saying whether it wants to see your fire risk assessment. Fire safety law still says the landlord of an HMO must have one.
Can I do my own HMO fire risk assessment in South Kesteven?
The council says a "competent person" must carry it out. In fire safety law that means someone with enough training, experience or knowledge to assess the house properly. A careful landlord can meet that.
Which fire safety standard does South Kesteven use for HMOs?
South Kesteven publishes "Prescribed Standards for deciding the suitability for occupation of a House of Multiple Occupation (South Kesteven District Council)" (June 2021). Like most councils, it builds on the national LACORS guide.
What fire alarm does a 3-storey shared house need in South Kesteven?
For a typical 3-storey shared house with 6 tenants, South Kesteven's rules work out at Grade A, LD2. Your house may need something different depending on its layout, so check it properly with a fire risk assessment.