Rushmoor HMO fire safety requirements

Rushmoor publishes its own HMO fire safety standard, "What you need to know about owning or managing Houses in Multiple Occupation (HMOs) in Rushmoor" (September 2019).

Is a fire risk assessment needed for the licence?

Expected, but not sent in

The council's guidance talks about fire risk assessments, but it does not ask you to send one with your application. Fire safety law still says you need one.

Who can carry it out?

A "competent person"

The council says a "competent person" must carry it out. In fire safety law that means someone with enough training, experience or knowledge to assess the house properly. A careful landlord can meet that.

Which standard applies?

What you need to know about owning or managing Houses in Multiple Occupation (HMOs) in Rushmoor

Published September 2019.

Read the council's document →

When did we last check?

14 October 2026

We re-check every council's documents each month and update this page when they change.

What Rushmoor expects in 3 typical HMOs

Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.

2-storey shared house, 5 tenants

Fire alarm system
Grade D1, LD2
Fire doors on bedrooms
Not required
Fire door on the kitchen
Not required
Protected escape route
Not required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended

3-storey shared house, 6 tenants

Fire alarm system
Grade D1, LD2
Fire doors on bedrooms
Required*
Fire door on the kitchen
Required*
Protected escape route
Required*
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended

3-storey bedsits with cooking in rooms, 6 tenants

Fire alarm system
Grade A, LD1, plus a linked heat detector and a standalone smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended
  • Grade D1 (mains alarms with a sealed backup battery)
  • Grade A (a panel system with call points)
  • LD2 (escape route plus rooms where fires are likely to start)
  • LD1 (alarms in all rooms and on the escape route)
  • * The council's own standard asks for less here, so we show the LACORS minimum. We never go below LACORS.

In the council's own words

The wording these requirements come from, quoted from the published documents.

Fire alarms

Council's own standard

“Shared house Grade D1, LD2(D) up to three storeys ... Shared house Grade D1, LD1(J) four storeys or more ... All bedsits Grade D1, LD2(D) ... Bedsits Grade A, LD1(J) (N) three storeys system ... Additional non-interlinked smoke alarm with integral battery back-up in each bedsit”
What you need to know about owning or managing Houses in Multiple Occupation (HMOs) in Rushmoor, September 2019

Fire doors

Council's own standard

“No fire doors are ... fire doors to all risk ... rooms including kitchens”
What you need to know about owning or managing Houses in Multiple Occupation (HMOs) in Rushmoor, September 2019

Escape route

Council's own standard

“A 30-minute ... protected escape ... route is required to ... No fire doors are”
What you need to know about owning or managing Houses in Multiple Occupation (HMOs) in Rushmoor, September 2019

Kitchen heat detector

LACORS national guide

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Emergency lighting

Council's own standard

“There is no ... requirement for ... emergency lighting ... A system of ... emergency lighting ... is required in a ... shared house if the ... escape route is long”
What you need to know about owning or managing Houses in Multiple Occupation (HMOs) in Rushmoor, September 2019

Fire extinguishers

LACORS national guide

“a simple multi-purpose extinguisher is recommended on each floor in the common parts of HMOs and buildings containing flats.”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Spotted something out of date? Tell us and we will check it.

Common questions

Do I need a fire risk assessment for a Rushmoor HMO licence?
The council's guidance talks about fire risk assessments, but it does not ask you to send one with your application. Fire safety law still says you need one.
Can I do my own HMO fire risk assessment in Rushmoor?
The council says a "competent person" must carry it out. In fire safety law that means someone with enough training, experience or knowledge to assess the house properly. A careful landlord can meet that.
Which fire safety standard does Rushmoor use for HMOs?
Rushmoor publishes "What you need to know about owning or managing Houses in Multiple Occupation (HMOs) in Rushmoor" (September 2019). Like most councils, it builds on the national LACORS guide.
What fire alarm does a 3-storey shared house need in Rushmoor?
For a typical 3-storey shared house with 6 tenants, Rushmoor's rules work out at Grade D1, LD2. Your house may need something different depending on its layout, so check it properly with a fire risk assessment.

Check your Rushmoor HMO against the council's standard

Answer plain-English questions about your house and get a fire risk assessment report built on Rushmoor's rules. £45, no subscription.