Skip to main content
£45 one-off •Your fire risk assessment in 35 minutes •No subscription

South East

Runnymede HMO fire safety requirements

Runnymede publishes its own HMO fire safety standard, "Standards for Houses in Multiple Occupation (HMO's): A landlord's guide (Runnymede Borough Council)" (Updated June 2023).

Is a fire risk assessment needed for the licence?

Not stated by the council

We could not find the council saying whether it wants to see your fire risk assessment. Fire safety law still says the landlord of an HMO must have one.

Who can carry it out?

No rule on who writes it

The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.

Which standard applies?

Standards for Houses in Multiple Occupation (HMO's): A landlord's guide (Runnymede Borough Council)

Published Updated June 2023.

Read the council's document →

When did we last check?

12 October 2026

We re-check every council's documents each month and update this page when they change.

What Runnymede expects in 3 typical HMOs

Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.

2-storey shared house, 5 tenants

Fire alarm system
Grade D1, LD2
Fire doors on bedrooms
Not required
Fire door on the kitchen
Required
Protected escape route
Not required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Not required

3-storey shared house, 6 tenants

Fire alarm system
Grade A, LD1, plus a linked smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Required
Fire blanket in the kitchen
Required
Fire extinguishers
Not required

3-storey bedsits with cooking in rooms, 6 tenants

Fire alarm system
Grade A, LD1, plus a linked heat detector and a standalone smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Required
Fire blanket in the kitchen
Required
Fire extinguishers
Not required
  • Grade D1 (mains alarms with a sealed backup battery)
  • Grade A (a panel system with call points)
  • LD2 (escape route plus rooms where fires are likely to start)
  • LD1 (alarms in all rooms and on the escape route)

In the council's own words

The wording these requirements come from, quoted from the published documents.

Fire alarms

Council's own standard

“Install mains operated interlinked smoke alarms to the ground floor hallway, the first-floor landing and living room with a heat alarm in the kitchen ... The system should comply with the requirements of BS5839, Part 6, Grade D1, LD2 ... The system should comply with the recommendations of BS 5839: Part 6, Type LD1, Grade A ... smoke detectors in each bedroom and throughout communal hallways/escape routes”
Standards for Houses in Multiple Occupation (HMO's): A landlord's guide (Runnymede Borough Council), Updated June 2023

Fire doors

LACORS national guide

“30-minute protected route note 8, is required, including 30-minute fire-resisting construction and FD30 doors to all risk rooms (without smoke seals ... 30-minute fire-resisting construction and FD30S doors to all risk rooms. Travel distance must not be excessive”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Escape route

LACORS national guide

“No requirement for full 30-minute protected route note 7, but the escape route should have sound, traditional construction and should not pass through risk rooms ... 30-minute protected route note 8, is required, including 30-minute fire-resisting construction”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Kitchen heat detector

LACORS national guide

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Emergency lighting

Council's own standard

“Provision of suitable and sufficient escape lighting throughout the common parts of the building”
Standards for Houses in Multiple Occupation (HMO's): A landlord's guide (Runnymede Borough Council), Updated June 2023

Fire extinguishers

Council's own standard

“Fire extinguishers are not required unless your fire risk assessment identifies them as being appropriate”
Standards for Houses in Multiple Occupation (HMO's): A landlord's guide (Runnymede Borough Council), Updated June 2023

Spotted something out of date? Tell us and we will check it.

Common questions

Do I need a fire risk assessment for a Runnymede HMO licence?
We could not find the council saying whether it wants to see your fire risk assessment. Fire safety law still says the landlord of an HMO must have one.
Can I do my own HMO fire risk assessment in Runnymede?
The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.
Which fire safety standard does Runnymede use for HMOs?
Runnymede publishes "Standards for Houses in Multiple Occupation (HMO's): A landlord's guide (Runnymede Borough Council)" (Updated June 2023). Like most councils, it builds on the national LACORS guide.
What fire alarm does a 3-storey shared house need in Runnymede?
For a typical 3-storey shared house with 6 tenants, Runnymede's rules work out at Grade A, LD1, plus a linked smoke alarm in each letting. Your house may need something different depending on its layout, so check it properly with a fire risk assessment.

Check your Runnymede HMO against the council's standard

Answer plain-English questions about your house and get a fire risk assessment report built on Runnymede's rules. £45, no subscription.