Redbridge HMO fire safety requirements

Redbridge publishes its own HMO fire safety standard, "Mandatory HMO licence conditions" (Not dated (live page, fetched 28 September 2026)).

Is a fire risk assessment needed for the licence?

Yes, as a licence condition

You need a written fire risk assessment as a condition of the licence, and the council can ask to see it at any time.

Who can carry it out?

No rule on who writes it

The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.

Which standard applies?

Mandatory HMO licence conditions

Published Not dated (live page, fetched 28 September 2026).

Read the council's document →

When did we last check?

15 October 2026

We re-check every council's documents each month and update this page when they change.

What Redbridge expects in 3 typical HMOs

Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.

2-storey shared house, 5 tenants

Fire alarm system
Grade D2, LD2, plus a linked smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended

3-storey shared house, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended

3-storey bedsits with cooking in rooms, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked heat detector and a standalone smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended
  • Grade D2 (mains alarms with a replaceable backup battery)
  • Grade A (a panel system with call points)
  • LD2 (escape route plus rooms where fires are likely to start)

In the council's own words

The wording these requirements come from, quoted from the published documents.

Fire alarms

Council's own standard

“Grade A, LD2 systems are required in all HMO properties which have three or more storeys including basements ... Grade D, LD2 systems are required in all HMO properties of up to two storeys high ... which will include all rooms used as bedrooms, communal living rooms, shared kitchens and basements”
Mandatory HMO licence conditions (London Borough of Redbridge), Not dated (live page)

Fire doors

Council's own standard

“all doors to rooms used as bedrooms, communal living rooms, shared kitchens and the door to any under stairs cupboard if housing supply meters or electrical consumer units shall be 30-minute fire resisting doors (FD30S)”
Mandatory HMO licence conditions (London Borough of Redbridge), Not dated (live page)

Escape route

Council's own standard

“all walls in the HMO that separate rooms used as bedrooms, communal living rooms and shared kitchens from the staircase enclosure shall provide 30 minutes fire resistance from the room side of the wall”
Mandatory HMO licence conditions (London Borough of Redbridge), Not dated (live page)

Kitchen heat detector

LACORS national guide

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Emergency lighting

Council's own standard

“Emergency lighting of the means of escape route is only required in larger buildings with long escape routes, buildings with a complex layout, buildings with no natural or borrowed lighting in the escape route, or buildings with vulnerable occupiers.”
Mandatory HMO licence conditions (London Borough of Redbridge), Not dated (live page)

Fire extinguishers

LACORS national guide

“a simple multi-purpose extinguisher is recommended on each floor in the common parts of HMOs and buildings containing flats.”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Spotted something out of date? Tell us and we will check it.

Common questions

Do I need a fire risk assessment for a Redbridge HMO licence?
You need a written fire risk assessment as a condition of the licence, and the council can ask to see it at any time.
Can I do my own HMO fire risk assessment in Redbridge?
The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.
Which fire safety standard does Redbridge use for HMOs?
Redbridge publishes "Mandatory HMO licence conditions" (Not dated (live page, fetched 28 September 2026)). Like most councils, it builds on the national LACORS guide.
What fire alarm does a 3-storey shared house need in Redbridge?
For a typical 3-storey shared house with 6 tenants, Redbridge's rules work out at Grade A, LD2, plus a linked smoke alarm in each letting. Your house may need something different depending on its layout, so check it properly with a fire risk assessment.

Check your Redbridge HMO against the council's standard

Answer plain-English questions about your house and get a fire risk assessment report built on Redbridge's rules. £45, no subscription.