Oxford HMO fire safety requirements
Oxford publishes its own HMO fire safety standard, "Landlord's Guide to Amenities and Facilities for Houses in Multiple Occupation (Oxford City Council)" (2019).
Is a fire risk assessment needed for the licence?
Yes, with your licence application
The council lists a written fire risk assessment as one of the documents you send with your HMO licence application.
Who can carry it out?
No rule on who writes it
The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.
Which standard applies?
Landlord's Guide to Amenities and Facilities for Houses in Multiple Occupation (Oxford City Council)
Published 2019.
Read the council's document →When did we last check?
15 October 2026
We re-check every council's documents each month and update this page when they change.
What Oxford expects in 3 typical HMOs
Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.
2-storey shared house, 5 tenants
- Fire alarm system
- Grade D2, LD2
- Fire doors on bedrooms
- Recommended
- Fire door on the kitchen
- Required
- Protected escape route
- Recommended
- Heat detector in the kitchen
- Required
- Emergency lighting
- Not required
- Fire blanket in the kitchen
- Required
- Fire extinguishers
- Not required
3-storey shared house, 6 tenants
- Fire alarm system
- Grade D2, LD2
- Fire doors on bedrooms
- Required*
- Fire door on the kitchen
- Required
- Protected escape route
- Required*
- Heat detector in the kitchen
- Required
- Emergency lighting
- Not required
- Fire blanket in the kitchen
- Required
- Fire extinguishers
- Not required
3-storey bedsits with cooking in rooms, 6 tenants
- Fire alarm system
- Grade A, LD2, plus a linked heat detector and a standalone smoke alarm in each letting
- Fire doors on bedrooms
- Required
- Fire door on the kitchen
- Required
- Protected escape route
- Required
- Heat detector in the kitchen
- Required
- Emergency lighting
- Not required
- Fire blanket in the kitchen
- Required
- Fire extinguishers
- Not required
| Requirement | 2-storey shared house, 5 tenants | 3-storey shared house, 6 tenants | 3-storey bedsits with cooking in rooms, 6 tenants |
|---|---|---|---|
| Fire alarm system | Grade D2, LD2 | Grade D2, LD2 | Grade A, LD2, plus a linked heat detector and a standalone smoke alarm in each letting |
| Fire doors on bedrooms | Recommended | Required* | Required |
| Fire door on the kitchen | Required | Required | Required |
| Protected escape route | Recommended | Required* | Required |
| Heat detector in the kitchen | Required | Required | Required |
| Emergency lighting | Not required | Not required | Not required |
| Fire blanket in the kitchen | Required | Required | Required |
| Fire extinguishers | Not required | Not required | Not required |
- Grade D2 (mains alarms with a replaceable backup battery)
- Grade A (a panel system with call points)
- LD2 (escape route plus rooms where fires are likely to start)
- * The council's own standard asks for less here, so we show the LACORS minimum. We never go below LACORS.
In the council's own words
The wording these requirements come from, quoted from the published documents.
Fire alarms
Council's own standard
“Low risk shared houses (shared kitchen facilities and joint tenancy agreement) ... Grade D LD2 fire alarm system with smoke detectors in escape route at all levels and heat alarm in kitchen (interlinked)”
Fire doors
Council's own standard
“Bedroom doors must be solid and close fitting ... Bedroom doors must be 30-minute fire doors with heat seals, smoke seals and self-closer1”
Escape route
Council's own standard
“Basement/cellars must have a ceiling that is 30-minute fire resistant ... = Best practice 30-minute protected escape route”
Kitchen heat detector
LACORS national guide
“additional interlinked heat alarm with integral battery back-up located in the kitchen”
Emergency lighting
Council's own standard
“Emergency lighting is not normally required in small, low risk HMOs. Where the escape route is long or complicated or there is no effective borrowed light then emergency lighting is required.”
Fire extinguishers
Council's own standard
“Fire extinguishers are no longer asked for. If landlords wish to provide extinguishers, then tenants must be trained in use of equipment and the landlord must service them annually.”
Spotted something out of date? Tell us and we will check it.
Common questions
Do I need a fire risk assessment for a Oxford HMO licence?
Can I do my own HMO fire risk assessment in Oxford?
Which fire safety standard does Oxford use for HMOs?
What fire alarm does a 3-storey shared house need in Oxford?
Check your Oxford HMO against the council's standard
Answer plain-English questions about your house and get a fire risk assessment report built on Oxford's rules. £45, no subscription.