Skip to main content
£45 one-off •Your fire risk assessment in 35 minutes •No subscription

East of England

North Hertfordshire HMO fire safety requirements

North Hertfordshire publishes its own HMO fire safety standard, "Policy for Licensing Houses in Multiple Occupation, Appendix B: Guide to fire safety for houses in multiple occupation (Herts authorities and HFRS)" (February 2023). It is based on the Hertfordshire standard, which 2 other councils use too.

Is a fire risk assessment needed for the licence?

Yes, with your licence application

The council lists a written fire risk assessment as one of the documents you send with your HMO licence application.

Who can carry it out?

No rule on who writes it

The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.

Which standard applies?

Policy for Licensing Houses in Multiple Occupation, Appendix B: Guide to fire safety for houses in multiple occupation (Herts authorities and HFRS)

Published February 2023.

Read the council's document →

When did we last check?

11 October 2026

We re-check every council's documents each month and update this page when they change.

What North Hertfordshire expects in 3 typical HMOs

Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.

2-storey shared house, 5 tenants

Fire alarm system
Grade D2, LD3
Fire doors on bedrooms
Not required
Fire door on the kitchen
Not required
Protected escape route
Not required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Not advised

3-storey shared house, 6 tenants

Fire alarm system
Grade D2, LD3
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Not advised

3-storey bedsits with cooking in rooms, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked heat detector and a standalone smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Required
Fire blanket in the kitchen
Required
Fire extinguishers
Not advised
  • Grade D2 (mains alarms with a replaceable backup battery)
  • Grade A (a panel system with call points)
  • LD3 (escape route only)
  • LD2 (escape route plus rooms where fires are likely to start)

In the council's own words

The wording these requirements come from, quoted from the published documents.

Fire alarms

Council's own standard

“BS5839-6 (2019) has changed the requirements for HMO premises of 1-2 stories (below 200m2) for new or materially altered premises, which will now require a grade D category LD1 rather than LD2. Existing premises remain compliant if they have a category LD2.”
Policy for Licensing HMOs, Appendix B: Guide to fire safety for houses in multiple occupation (North Hertfordshire District Council), February 2023

Fire doors

LACORS national guide

“30-minute protected route note 8, is required, including 30-minute fire-resisting construction and FD30 doors to all risk rooms (without smoke seals ... 30-minute fire-resisting construction and FD30S doors to all risk rooms. Travel distance must not be excessive”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Escape route

LACORS national guide

“No requirement for full 30-minute protected route note 7, but the escape route should have sound, traditional construction and should not pass through risk rooms ... 30-minute protected route note 8, is required, including 30-minute fire-resisting construction”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Kitchen heat detector

LACORS national guide

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Emergency lighting

Shared regional standard

“To be provided in accordance with the current BS 5266 Part 1 (or equivalent) ... to cover the protected escape route.”
Guide to Fire Safety in Houses in Multiple Occupation, Version 3 (Herts authorities and HFRS, Broxbourne copy), September 2015

Fire extinguishers

Shared regional standard

“on balance it is best to encourage people to get out of the house quickly and call the Fire Service ... Therefore, whilst fire blankets should be provided to all cooking facilities normally there will be no requirement for fire extinguishers.”
Guide to Fire Safety in Houses in Multiple Occupation, Version 3 (Herts authorities and HFRS, Broxbourne copy), September 2015

Spotted something out of date? Tell us and we will check it.

Not in North Hertfordshire?

Councils using the same standard as North Hertfordshire

Common questions

Do I need a fire risk assessment for a North Hertfordshire HMO licence?
The council lists a written fire risk assessment as one of the documents you send with your HMO licence application.
Can I do my own HMO fire risk assessment in North Hertfordshire?
The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.
Which fire safety standard does North Hertfordshire use for HMOs?
North Hertfordshire publishes "Policy for Licensing Houses in Multiple Occupation, Appendix B: Guide to fire safety for houses in multiple occupation (Herts authorities and HFRS)" (February 2023).
What fire alarm does a 3-storey shared house need in North Hertfordshire?
For a typical 3-storey shared house with 6 tenants, North Hertfordshire's rules work out at Grade D2, LD3. Your house may need something different depending on its layout, so check it properly with a fire risk assessment.

Check your North Hertfordshire HMO against the council's standard

Answer plain-English questions about your house and get a fire risk assessment report built on North Hertfordshire's rules. £45, no subscription.