North East Lincolnshire HMO fire safety requirements
North East Lincolnshire publishes its own HMO fire safety standard, "Building Control Guidance Note No. 34: Rooms for Residential Purposes (Including HMO Definition) (North East Lincolnshire Council)" (NELC/GN034/V2/0219, uploaded September 2026).
Is a fire risk assessment needed for the licence?
Yes, with your licence application
The council lists a written fire risk assessment as one of the documents you send with your HMO licence application.
Who can carry it out?
No rule on who writes it
The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.
Which standard applies?
Building Control Guidance Note No. 34: Rooms for Residential Purposes (Including HMO Definition) (North East Lincolnshire Council)
Published NELC/GN034/V2/0219, uploaded September 2026.
Read the council's document →When did we last check?
14 October 2026
We re-check every council's documents each month and update this page when they change.
What North East Lincolnshire expects in 3 typical HMOs
Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.
2-storey shared house, 5 tenants
- Fire alarm system
- Grade D2, LD3
- Fire doors on bedrooms
- Not required
- Fire door on the kitchen
- Not required
- Protected escape route
- Not required
- Heat detector in the kitchen
- Required
- Emergency lighting
- Not required
- Fire blanket in the kitchen
- Required
- Fire extinguishers
- Recommended
3-storey shared house, 6 tenants
- Fire alarm system
- Grade D2, LD3
- Fire doors on bedrooms
- Required
- Fire door on the kitchen
- Required
- Protected escape route
- Required
- Heat detector in the kitchen
- Required
- Emergency lighting
- Not required
- Fire blanket in the kitchen
- Required
- Fire extinguishers
- Recommended
3-storey bedsits with cooking in rooms, 6 tenants
- Fire alarm system
- Grade A, LD2, plus a linked heat detector and a standalone smoke alarm in each letting
- Fire doors on bedrooms
- Required
- Fire door on the kitchen
- Required
- Protected escape route
- Required
- Heat detector in the kitchen
- Required
- Emergency lighting
- Not required
- Fire blanket in the kitchen
- Required
- Fire extinguishers
- Recommended
| Requirement | 2-storey shared house, 5 tenants | 3-storey shared house, 6 tenants | 3-storey bedsits with cooking in rooms, 6 tenants |
|---|---|---|---|
| Fire alarm system | Grade D2, LD3 | Grade D2, LD3 | Grade A, LD2, plus a linked heat detector and a standalone smoke alarm in each letting |
| Fire doors on bedrooms | Not required | Required | Required |
| Fire door on the kitchen | Not required | Required | Required |
| Protected escape route | Not required | Required | Required |
| Heat detector in the kitchen | Required | Required | Required |
| Emergency lighting | Not required | Not required | Not required |
| Fire blanket in the kitchen | Required | Required | Required |
| Fire extinguishers | Recommended | Recommended | Recommended |
- Grade D2 (mains alarms with a replaceable backup battery)
- Grade A (a panel system with call points)
- LD3 (escape route only)
- LD2 (escape route plus rooms where fires are likely to start)
In the council's own words
The wording these requirements come from, quoted from the published documents.
Fire alarms
Council's own standard
“Smoke alarms must be mains operated with battery back-up, in accordance with British Standard 5839 (Part 1). The smoke alarms are to be interlinked ... Approved automatic smoke detectors located in all bedroom areas, all other rooms including common areas ... Approved automatic heat detectors located in areas such as kitchens ... Manually operated call points to be provided at every final exit from property”
Fire doors
Council's own standard
“Generally, 30 minutes, self closing, fire resisting door sets must be fitted to all doors of all rooms leading onto the hall, stairs and landings”
Escape route
Council's own standard
“Means of escape is by way of the formation of a protected route centred around the staircase, internal landings and hallway”
Kitchen heat detector
LACORS national guide
“additional interlinked heat alarm with integral battery back-up located in the kitchen”
Emergency lighting
Council's own standard
“emergency lighting is required to be installed within the protected route of the property”
Fire extinguishers
LACORS national guide
“a simple multi-purpose extinguisher is recommended on each floor in the common parts of HMOs and buildings containing flats.”
Spotted something out of date? Tell us and we will check it.
Not in North East Lincolnshire?
Common questions
Do I need a fire risk assessment for a North East Lincolnshire HMO licence?
Can I do my own HMO fire risk assessment in North East Lincolnshire?
Which fire safety standard does North East Lincolnshire use for HMOs?
What fire alarm does a 3-storey shared house need in North East Lincolnshire?