Newham HMO fire safety requirements

Newham publishes its own HMO fire safety standard, "Fire Safety guidance in HMO properties" (Not dated (cites BS 5839-6:2019)).

Is a fire risk assessment needed for the licence?

Yes, with your licence application

The council lists a written fire risk assessment as one of the documents you send with your HMO licence application.

Who can carry it out?

No rule on who writes it

The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.

Which standard applies?

Fire Safety guidance in HMO properties

Published Not dated (cites BS 5839-6:2019).

Read the council's document →

When did we last check?

14 October 2026

We re-check every council's documents each month and update this page when they change.

What Newham expects in 3 typical HMOs

Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.

2-storey shared house, 5 tenants

Fire alarm system
Grade D1, LD2
Fire doors on bedrooms
Not required
Fire door on the kitchen
Not required
Protected escape route
Not required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended

3-storey shared house, 6 tenants

Fire alarm system
Grade D1, LD2
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended

3-storey bedsits with cooking in rooms, 6 tenants

Fire alarm system
Grade A, LD1, plus a linked heat detector and a standalone smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended
  • Grade D1 (mains alarms with a sealed backup battery)
  • Grade A (a panel system with call points)
  • LD2 (escape route plus rooms where fires are likely to start)
  • LD1 (alarms in all rooms and on the escape route)

In the council's own words

The wording these requirements come from, quoted from the published documents.

Fire alarms

Council's own standard

“BEDSIT TYPE HMO – up to 2 STOREYS ... Grade D1 Category LD1 (BS5839-6:2019) ... Bedrooms without cooking facilities - mains wired interlinked smoke alarms ... Bedrooms with cooking facilities - mains wired interlinked heat detectors plus a non- interlinked smoke alarms ... BEDSIT TYPE HMO – 3 or 4 STOREYS ... Grade A Category LD1 (BS5839-6: 2019) ... in all bedrooms and areas that present a high risk to occupants ... SHARED HOUSE HMO – UP TO 2 STOREYS ... Grade D1 Category LD2 (BS5839-6:2019) ... SHARED HOUSE HMO – 3 or 4 STOREYS ... Grade D1 Category LD2 (BS5839-6 : 2019)”
Fire Safety guidance in HMO properties (London Borough of Newham), Not dated

Fire doors

Council's own standard

“All doors leading onto the escape route must be fire doors providing 30 minute fire protection ... Fire doors 30 minute protection on all exits on to the protected route ... Doors leading onto the escape route must be close fitting solid timber or panelled of substantial construction”
Fire Safety guidance in HMO properties (London Borough of Newham), Not dated

Escape route

Council's own standard

“Property must have a 30 minute minimum protected route, therefore walls and floors must be of sound construction ... Property must have a route that leads to a place of ultimate safety.”
Fire Safety guidance in HMO properties (London Borough of Newham), Not dated

Kitchen heat detector

LACORS national guide

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Emergency lighting

LACORS national guide

“Emergency escape lighting required only if the route is long or complex or where there is no effective borrowed light ... Shared house HMO of five or six storeys (shared cooking facilities) Conventional lighting and emergency escape lighting”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Fire extinguishers

LACORS national guide

“a simple multi-purpose extinguisher is recommended on each floor in the common parts of HMOs and buildings containing flats.”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Spotted something out of date? Tell us and we will check it.

Common questions

Do I need a fire risk assessment for a Newham HMO licence?
The council lists a written fire risk assessment as one of the documents you send with your HMO licence application.
Can I do my own HMO fire risk assessment in Newham?
The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.
Which fire safety standard does Newham use for HMOs?
Newham publishes "Fire Safety guidance in HMO properties" (Not dated (cites BS 5839-6:2019)). Like most councils, it builds on the national LACORS guide.
What fire alarm does a 3-storey shared house need in Newham?
For a typical 3-storey shared house with 6 tenants, Newham's rules work out at Grade D1, LD2. Your house may need something different depending on its layout, so check it properly with a fire risk assessment.

Check your Newham HMO against the council's standard

Answer plain-English questions about your house and get a fire risk assessment report built on Newham's rules. £45, no subscription.