Merton HMO fire safety requirements

Merton publishes its own HMO fire safety standard, "Guidance on Fire Safety, Privately Rented Properties (London Borough of Merton)" (June 2026).

Is a fire risk assessment needed for the licence?

Expected, but not sent in

The council's guidance talks about fire risk assessments, but it does not ask you to send one with your application. Fire safety law still says you need one.

Who can carry it out?

No rule on who writes it

The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.

Which standard applies?

Guidance on Fire Safety, Privately Rented Properties (London Borough of Merton)

Published June 2026.

Read the council's document →

When did we last check?

15 October 2026

We re-check every council's documents each month and update this page when they change.

What Merton expects in 3 typical HMOs

Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.

2-storey shared house, 5 tenants

Fire alarm system
Grade D1, LD2
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Required

3-storey shared house, 6 tenants

Fire alarm system
Grade D1, LD2
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Required

3-storey bedsits with cooking in rooms, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked heat detector and a standalone smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Required
  • Grade D1 (mains alarms with a sealed backup battery)
  • Grade A (a panel system with call points)
  • LD2 (escape route plus rooms where fires are likely to start)

In the council's own words

The wording these requirements come from, quoted from the published documents.

Fire alarms

Council's own standard

“Small HMOs (3 to 4 unrelated occupants) ... Grade D1, LD2 coverage system: interlinked smoke detection in circulation spaces on each floor, linked smoke detection in living room(s), and linked heat detection in the kitchen. ... Large HMOs (5 and more Unrelated Occupants) ... Grade D1, LD2 coverage system: interlinked smoke detection in circulation spaces on each floor, linked smoke detection in occupied units, including shared living rooms and linked heat detection in the kitchen. ... Grade A, LD2 coverage system: higher-risk HMOs, including bedsit ac- commodation, hostels, properties with cooking facilities within individual ... units, complex layouts, or higher-risk occupancy profiles. ... Grade D1, LD2 coverage system: in shared houses type of HMOs”
Guidance on Fire Safety, Privately Rented Properties (London Borough of Merton), June 2026

Fire doors

Council's own standard

“with all doors opening onto the route from risk rooms (shared kitchens, living rooms and occupied units) fitted with FD30S fire doors incorporating suitable self-closing devices”
Guidance on Fire Safety, Privately Rented Properties (London Borough of Merton), June 2026

Escape route

Council's own standard

“A protected means of escape providing a minimum of 30 minutes' fire and smoke resistance is required.”
Guidance on Fire Safety, Privately Rented Properties (London Borough of Merton), June 2026

Kitchen heat detector

LACORS national guide

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Emergency lighting

LACORS national guide

“Emergency escape lighting required only if the route is long or complex or where there is no effective borrowed light ... Shared house HMO of five or six storeys (shared cooking facilities) Conventional lighting and emergency escape lighting”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Fire extinguishers

Council's own standard

“Additional Fire precautions: fire blankets and 3kg CO2 extinguisher in shared kitchen.”
Guidance on Fire Safety, Privately Rented Properties (London Borough of Merton), June 2026

Spotted something out of date? Tell us and we will check it.

Common questions

Do I need a fire risk assessment for a Merton HMO licence?
The council's guidance talks about fire risk assessments, but it does not ask you to send one with your application. Fire safety law still says you need one.
Can I do my own HMO fire risk assessment in Merton?
The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.
Which fire safety standard does Merton use for HMOs?
Merton publishes "Guidance on Fire Safety, Privately Rented Properties (London Borough of Merton)" (June 2026). Like most councils, it builds on the national LACORS guide.
What fire alarm does a 3-storey shared house need in Merton?
For a typical 3-storey shared house with 6 tenants, Merton's rules work out at Grade D1, LD2. Your house may need something different depending on its layout, so check it properly with a fire risk assessment.