East of England

Ipswich HMO fire safety requirements

Ipswich publishes its own HMO fire safety standard, "Houses in Multiple Occupation: Landlord's Handbook (Ipswich Borough Council)" (September 2018).

Is a fire risk assessment needed for the licence?

Not stated by the council

We could not find the council saying whether it wants to see your fire risk assessment. Fire safety law still says the landlord of an HMO must have one.

Who can carry it out?

No rule on who writes it

The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.

Which standard applies?

Houses in Multiple Occupation: Landlord's Handbook (Ipswich Borough Council)

Published September 2018.

Read the council's document →

When did we last check?

15 October 2026

We re-check every council's documents each month and update this page when they change.

What Ipswich expects in 3 typical HMOs

Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.

2-storey shared house, 5 tenants

Fire alarm system
Grade D2, LD3
Fire doors on bedrooms
Not required
Fire door on the kitchen
Not required
Protected escape route
Not required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Required

3-storey shared house, 6 tenants

Fire alarm system
Grade D2, LD3
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Required

3-storey bedsits with cooking in rooms, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked heat detector and a linked smoke alarm in each letting*
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Required
Fire blanket in the kitchen
Required
Fire extinguishers
Required
  • Grade D2 (mains alarms with a replaceable backup battery)
  • Grade A (a panel system with call points)
  • LD3 (escape route only)
  • LD2 (escape route plus rooms where fires are likely to start)
  • * The council's own standard asks for less here, so we show the LACORS minimum. We never go below LACORS.

In the council's own words

The wording these requirements come from, quoted from the published documents.

Fire alarms

Council's own standard

“mains wired interlinked optical type smoke detectors/alarms in common parts, basement/cellar and in all habitable rooms and a heat detector in the kitchen (BS 5839-6 Grade D, LD2) ... kitchen (BS 5839-6 Grade A, LD2)”
Houses in Multiple Occupation: Landlord's Handbook (Ipswich Borough Council), September 2018

Fire doors

LACORS national guide

“30-minute protected route note 8, is required, including 30-minute fire-resisting construction and FD30 doors to all risk rooms (without smoke seals ... 30-minute fire-resisting construction and FD30S doors to all risk rooms. Travel distance must not be excessive”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Escape route

LACORS national guide

“No requirement for full 30-minute protected route note 7, but the escape route should have sound, traditional construction and should not pass through risk rooms ... 30-minute protected route note 8, is required, including 30-minute fire-resisting construction”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Kitchen heat detector

LACORS national guide

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Emergency lighting

Council's own standard

“emergency lighting to common parts (BS5266-1) where the escape route is long or complex”
Houses in Multiple Occupation: Landlord's Handbook (Ipswich Borough Council), September 2018

Fire extinguishers

Council's own standard

“provision of a fire blanket and dry powder fire extinguisher in the kitchen and a 9 litre water extinguisher to each floor level”
Houses in Multiple Occupation: Landlord's Handbook (Ipswich Borough Council), September 2018

Spotted something out of date? Tell us and we will check it.

Common questions

Do I need a fire risk assessment for a Ipswich HMO licence?
We could not find the council saying whether it wants to see your fire risk assessment. Fire safety law still says the landlord of an HMO must have one.
Can I do my own HMO fire risk assessment in Ipswich?
The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.
Which fire safety standard does Ipswich use for HMOs?
Ipswich publishes "Houses in Multiple Occupation: Landlord's Handbook (Ipswich Borough Council)" (September 2018). Like most councils, it builds on the national LACORS guide.
What fire alarm does a 3-storey shared house need in Ipswich?
For a typical 3-storey shared house with 6 tenants, Ipswich's rules work out at Grade D2, LD3. Your house may need something different depending on its layout, so check it properly with a fire risk assessment.