Suffolk HMO fire safety standards

Suffolk councils share one Landlords' Handbook (2024), which sets out the fire safety they expect in an HMO.

Read the Suffolk document →

What the Suffolk standard expects in 3 typical HMOs

Your council may have changed some of the detail, so check your council's own page below.

2-storey shared house, 5 tenants

Fire alarm system
Grade D1, LD2
Fire doors on bedrooms
Not required
Fire door on the kitchen
Not required
Protected escape route
Not required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Required

3-storey shared house, 6 tenants

Fire alarm system
Grade D1, LD2
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Required

3-storey bedsits with cooking in rooms, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked heat detector in each letting*
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Required
  • Grade D1 (mains alarms with a sealed backup battery)
  • Grade A (a panel system with call points)
  • LD2 (escape route plus rooms where fires are likely to start)
  • * The council's own standard asks for less here, so we show the LACORS minimum. We never go below LACORS.

What the standard says

Fire alarms

Shared regional standard

“Shared house scenario - no more than 2 storeys ... Grade D1, Category LD2 automatic fire detection and alarm system. ... Shared house scenario - 4 storeys ... Grade D1, Category LD1 automatic fire detection and alarm system. ... Grade A, Category LD1 automatic fire detection and alarm system (new or materially altered ... Grade D, Category LD1 automatic fire detection and alarm system (existing premises) ... Individual dwelling units or bedsits comprising a single room including cooking facilities: ... Individual dwelling units, within the HMO, comprising two or more rooms: ... Communal areas of the HMO: ... Grade A, Category LD2 automatic fire detection and alarm system.”
Houses in Multiple Occupation: Suffolk Landlords' Handbook (Babergh and Mid Suffolk copy), 2 July 2024

Fire doors

LACORS national guide

“30-minute protected route note 8, is required, including 30-minute fire-resisting construction and FD30 doors to all risk rooms (without smoke seals ... 30-minute fire-resisting construction and FD30S doors to all risk rooms. Travel distance must not be excessive”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Escape route

LACORS national guide

“No requirement for full 30-minute protected route note 7, but the escape route should have sound, traditional construction and should not pass through risk rooms ... 30-minute protected route note 8, is required, including 30-minute fire-resisting construction”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Kitchen heat detector

LACORS national guide

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Emergency lighting

Shared regional standard

“Emergency lighting to common parts (BS 5266-1) where the escape route is long, dark or complex.”
Houses in Multiple Occupation: Suffolk Landlords' Handbook (Babergh and Mid Suffolk copy), 2 July 2024

Fire extinguishers

Shared regional standard

“Provision of a fire blanket and dry powder fire extinguisher in the kitchen.”
Houses in Multiple Occupation: Suffolk Landlords' Handbook (Babergh and Mid Suffolk copy), 2 July 2024

Common questions

Which councils use the Suffolk standard?
4 councils: Babergh, East Suffolk, Mid Suffolk, West Suffolk.
Is the Suffolk standard stricter than LACORS?
In some places, yes. Where it asks for more than LACORS, you need to meet it. Where it asks for less, or says nothing, we use the LACORS minimum instead.

Check your HMO against your council's standard

Answer plain-English questions about your house and get a fire risk assessment report built on your council's rules. £45, no subscription.