Chorley HMO fire safety requirements

Chorley publishes its own HMO fire safety standard, "South Ribble Borough Council and Chorley Borough Council, Houses in Multiple Occupation Guide and Amenity Standard 2024" (September 2024). It is based on the Lancashire standard, which 1 other council uses too.

Is a fire risk assessment needed for the licence?

Yes, with your licence application

The council lists a written fire risk assessment as one of the documents you send with your HMO licence application.

Who can carry it out?

A "competent person"

The council says a "competent person" must carry it out. In fire safety law that means someone with enough training, experience or knowledge to assess the house properly. A careful landlord can meet that.

Which standard applies?

South Ribble Borough Council and Chorley Borough Council, Houses in Multiple Occupation Guide and Amenity Standard 2024

Published September 2024.

Read the council's document →

When did we last check?

1 October 2026

We re-check every council's documents each month and update this page when they change.

What Chorley expects in 3 typical HMOs

Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.

2-storey shared house, 5 tenants

Fire alarm system
Grade D1, LD2, plus a linked smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended

3-storey shared house, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended

3-storey bedsits with cooking in rooms, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked heat detector and a standalone smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended
  • Grade D1 (mains alarms with a sealed backup battery)
  • Grade A (a panel system with call points)
  • LD2 (escape route plus rooms where fires are likely to start)

In the council's own words

The wording these requirements come from, quoted from the published documents.

Fire alarms

Shared regional standard

“Any floor/storey above 200m2 or 3 + Storeys ... Grade A LD2 fire alarm and detection system. See Note NO YES ... Existing HMO Grade D1 - LD2 fire alarm and detection system ... New or material altered (including converted dwellings) Grade D1- LD1 Fire alarm and detection system. ... No cooking facilities are included in the tenant dwelling. Additional interlinked smoke detector connected to the communal system ... Any type of cooking facilities included in the tenant dwelling. An additional interlinked heat detector connected to the communal system and an independent Grade D1 LD2 provided to the tenant dwelling. ... Individual dwelling units, within the HMO, comprising two or more rooms. – Addition to the communal system Grade D1 LD2”
South Ribble Borough Council and Chorley Borough Council, Houses in Multiple Occupation Guide and Amenity Standard 2024, September 2024

Fire doors

Shared regional standard

“Bedroom doors must be 30-minute fire doors with YES YES combination heat and smoke seal intumescent strips. Self-closers must be fitted.”
South Ribble Borough Council and Chorley Borough Council, Houses in Multiple Occupation Guide and Amenity Standard 2024, September 2024

Escape route

Shared regional standard

“Protected 30-minute protected escape route. YES YES”
South Ribble Borough Council and Chorley Borough Council, Houses in Multiple Occupation Guide and Amenity Standard 2024, September 2024

Kitchen heat detector

LACORS national guide

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Emergency lighting

LACORS national guide

“Emergency escape lighting required only if the route is long or complex or where there is no effective borrowed light ... Shared house HMO of five or six storeys (shared cooking facilities) Conventional lighting and emergency escape lighting”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Fire extinguishers

LACORS national guide

“a simple multi-purpose extinguisher is recommended on each floor in the common parts of HMOs and buildings containing flats.”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Spotted something out of date? Tell us and we will check it.

Not in Chorley?

Councils using the same standard as Chorley

Common questions

Do I need a fire risk assessment for a Chorley HMO licence?
The council lists a written fire risk assessment as one of the documents you send with your HMO licence application.
Can I do my own HMO fire risk assessment in Chorley?
The council says a "competent person" must carry it out. In fire safety law that means someone with enough training, experience or knowledge to assess the house properly. A careful landlord can meet that.
Which fire safety standard does Chorley use for HMOs?
Chorley publishes "South Ribble Borough Council and Chorley Borough Council, Houses in Multiple Occupation Guide and Amenity Standard 2024" (September 2024).
What fire alarm does a 3-storey shared house need in Chorley?
For a typical 3-storey shared house with 6 tenants, Chorley's rules work out at Grade A, LD2, plus a linked smoke alarm in each letting. Your house may need something different depending on its layout, so check it properly with a fire risk assessment.