Broadland HMO fire safety requirements
Broadland publishes its own HMO fire safety standard, "Amenity and Facility Standards for Houses in Multiple Occupation (Broadland District Council and South Norfolk Council)" (Reviewed 2023).
Is a fire risk assessment needed for the licence?
Expected, but not sent in
The council's guidance talks about fire risk assessments, but it does not ask you to send one with your application. Fire safety law still says you need one.
Who can carry it out?
No rule on who writes it
The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.
Which standard applies?
Amenity and Facility Standards for Houses in Multiple Occupation (Broadland District Council and South Norfolk Council)
Published Reviewed 2023.
Read the council's document →When did we last check?
29 September 2026
We re-check every council's documents each month and update this page when they change.
What Broadland expects in 3 typical HMOs
Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.
2-storey shared house, 5 tenants
- Fire alarm system
- Grade D2, LD3
- Fire doors on bedrooms
- Not required
- Fire door on the kitchen
- Not required
- Protected escape route
- Not required
- Heat detector in the kitchen
- Required
- Emergency lighting
- Not required
- Fire blanket in the kitchen
- Required
- Fire extinguishers
- Required
3-storey shared house, 6 tenants
- Fire alarm system
- Grade D2, LD3
- Fire doors on bedrooms
- Required
- Fire door on the kitchen
- Required
- Protected escape route
- Required
- Heat detector in the kitchen
- Required
- Emergency lighting
- Not required
- Fire blanket in the kitchen
- Required
- Fire extinguishers
- Required
3-storey bedsits with cooking in rooms, 6 tenants
- Fire alarm system
- Grade A, LD2, plus a linked heat detector and a standalone smoke alarm in each letting
- Fire doors on bedrooms
- Required
- Fire door on the kitchen
- Required
- Protected escape route
- Required
- Heat detector in the kitchen
- Required
- Emergency lighting
- Not required
- Fire blanket in the kitchen
- Required
- Fire extinguishers
- Required
| Requirement | 2-storey shared house, 5 tenants | 3-storey shared house, 6 tenants | 3-storey bedsits with cooking in rooms, 6 tenants |
|---|---|---|---|
| Fire alarm system | Grade D2, LD3 | Grade D2, LD3 | Grade A, LD2, plus a linked heat detector and a standalone smoke alarm in each letting |
| Fire doors on bedrooms | Not required | Required | Required |
| Fire door on the kitchen | Not required | Required | Required |
| Protected escape route | Not required | Required | Required |
| Heat detector in the kitchen | Required | Required | Required |
| Emergency lighting | Not required | Not required | Not required |
| Fire blanket in the kitchen | Required | Required | Required |
| Fire extinguishers | Required | Required | Required |
- Grade D2 (mains alarms with a replaceable backup battery)
- Grade A (a panel system with call points)
- LD3 (escape route only)
- LD2 (escape route plus rooms where fires are likely to start)
In the council's own words
The wording these requirements come from, quoted from the published documents.
Fire alarms
Shared regional standard
“BS 5839-6:2004 Grade D, LD2 fire alarm system with smoke detectors in escape route and (interlinked) heat detector in the kitchen.”
Fire doors
Shared regional standard
“All doors including Kitchen, living room, Bedrooms and Cellars must be 30-minute fire doors with heat and smoke seals and an overhead self-closing device.”
Escape route
Shared regional standard
“30-minute protected fire route.”
Kitchen heat detector
LACORS national guide
“additional interlinked heat alarm with integral battery back-up located in the kitchen”
Emergency lighting
Shared regional standard
“Emergency lighting to common parts (BS5266) where escape route is long or complex and there is no borrowed lighting”
Fire extinguishers
Shared regional standard
“Simple multipurpose fire extinguisher in a position such that they do not obstruct the escape route. ... Simple multipurpose fire extinguisher in common parts on each floor”
Spotted something out of date? Tell us and we will check it.
Not in Broadland?
Councils using the same standard as Broadland
Common questions
Do I need a fire risk assessment for a Broadland HMO licence?
Can I do my own HMO fire risk assessment in Broadland?
Which fire safety standard does Broadland use for HMOs?
What fire alarm does a 3-storey shared house need in Broadland?
Check your Broadland HMO against the council's standard
Answer plain-English questions about your house and get a fire risk assessment report built on Broadland's rules. £45, no subscription.