Brentwood HMO fire safety requirements

Brentwood publishes its own HMO fire safety standard, "Houses in Multiple Occupation: Adequate Means of Escape from Fire and Other Fire Precautions (Essex Chief Officers Specialist Housing Group)" (3rd Amendment November 2004).

Is a fire risk assessment needed for the licence?

Not stated by the council

We could not find the council saying whether it wants to see your fire risk assessment. Fire safety law still says the landlord of an HMO must have one.

Who can carry it out?

No rule on who writes it

The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.

Which standard applies?

Houses in Multiple Occupation: Adequate Means of Escape from Fire and Other Fire Precautions (Essex Chief Officers Specialist Housing Group)

Published 3rd Amendment November 2004.

Read the council's document →

When did we last check?

14 October 2026

We re-check every council's documents each month and update this page when they change.

What Brentwood expects in 3 typical HMOs

Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.

2-storey shared house, 5 tenants

Fire alarm system
Grade D2, LD3
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended

3-storey shared house, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended

3-storey bedsits with cooking in rooms, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked heat detector in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended
  • Grade D2 (mains alarms with a replaceable backup battery)
  • Grade A (a panel system with call points)
  • LD3 (escape route only)
  • LD2 (escape route plus rooms where fires are likely to start)

In the council's own words

The wording these requirements come from, quoted from the published documents.

Fire alarms

Council's own standard

“systems will be required in all 3 and 4 ... storey buildings.”
Houses in Multiple Occupation: Adequate Means of Escape from Fire and Other Fire Precautions (Essex Chief Officers Specialist Housing Group, used by Brentwood), 3rd Amendment November 2004

Fire doors

Council's own standard

“BS 8214: 1990 (FD 30s) half hour fire ... check doors to all rooms opening into ... protected stairway except WC/ bathroom”
Houses in Multiple Occupation: Adequate Means of Escape from Fire and Other Fire Precautions (Essex Chief Officers Specialist Housing Group, used by Brentwood), 3rd Amendment November 2004

Escape route

Council's own standard

“construction to be 30 Minutes fire resisting to British Standard 476 formed”
Houses in Multiple Occupation: Adequate Means of Escape from Fire and Other Fire Precautions (Essex Chief Officers Specialist Housing Group, used by Brentwood), 3rd Amendment November 2004

Kitchen heat detector

LACORS national guide

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Emergency lighting

Council's own standard

“too onerous to insist upon emergency”
Houses in Multiple Occupation: Adequate Means of Escape from Fire and Other Fire Precautions (Essex Chief Officers Specialist Housing Group, used by Brentwood), 3rd Amendment November 2004

Fire extinguishers

LACORS national guide

“a simple multi-purpose extinguisher is recommended on each floor in the common parts of HMOs and buildings containing flats.”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Spotted something out of date? Tell us and we will check it.

Common questions

Do I need a fire risk assessment for a Brentwood HMO licence?
We could not find the council saying whether it wants to see your fire risk assessment. Fire safety law still says the landlord of an HMO must have one.
Can I do my own HMO fire risk assessment in Brentwood?
The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.
Which fire safety standard does Brentwood use for HMOs?
Brentwood publishes "Houses in Multiple Occupation: Adequate Means of Escape from Fire and Other Fire Precautions (Essex Chief Officers Specialist Housing Group)" (3rd Amendment November 2004). Like most councils, it builds on the national LACORS guide.
What fire alarm does a 3-storey shared house need in Brentwood?
For a typical 3-storey shared house with 6 tenants, Brentwood's rules work out at Grade A, LD2, plus a linked smoke alarm in each letting. Your house may need something different depending on its layout, so check it properly with a fire risk assessment.