East of England

Breckland HMO fire safety requirements

Breckland publishes its own HMO fire safety standard, "Fire Precautions in Dwellings (Breckland Council, Private Sector Housing)" (March 2023).

Is a fire risk assessment needed for the licence?

Expected, but not sent in

The council's guidance talks about fire risk assessments, but it does not ask you to send one with your application. Fire safety law still says you need one.

Who can carry it out?

No rule on who writes it

The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.

Which standard applies?

Fire Precautions in Dwellings (Breckland Council, Private Sector Housing)

Published March 2023.

Read the council's document →

When did we last check?

15 October 2026

We re-check every council's documents each month and update this page when they change.

What Breckland expects in 3 typical HMOs

Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.

2-storey shared house, 5 tenants

Fire alarm system
Grade D1, LD2
Fire doors on bedrooms
Not required
Fire door on the kitchen
Required
Protected escape route
Not required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Required

3-storey shared house, 6 tenants

Fire alarm system
Grade D1, LD1
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Required

3-storey bedsits with cooking in rooms, 6 tenants

Fire alarm system
Grade A, LD1, plus a linked heat detector and a standalone smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Required
  • Grade D1 (mains alarms with a sealed backup battery)
  • Grade A (a panel system with call points)
  • LD2 (escape route plus rooms where fires are likely to start)
  • LD1 (alarms in all rooms and on the escape route)

In the council's own words

The wording these requirements come from, quoted from the published documents.

Fire alarms

Council's own standard

“The HMO must have close fitting doors to all risk rooms and a Grade D1 LD2 fire detection system with an additional Grade D1 interlinked heat detector to the kitchen(s). ... The HMO must have a fully protected means of escape and a Grade D1 LD1 fire detection system. ... Grade D1 LD1 system ... A mixed Grade A and Grade D1 smoke and heat detection system. ... FD30s door. Grade D1 heat detection ... Grade F1 or F2 smoke detector in each bedroom/unit ... Difference to assumption Property type Additional requirements”
Fire Precautions in Dwellings (Breckland Council, Private Sector Housing), March 2023

Fire doors

Council's own standard

“Kitchens within bedroom/unit HMOs – 1 & 2 stories FD30s door. Grade D1 heat detection”
Fire Precautions in Dwellings (Breckland Council, Private Sector Housing), March 2023

Escape route

LACORS national guide

“No requirement for full 30-minute protected route note 7, but the escape route should have sound, traditional construction and should not pass through risk rooms ... 30-minute protected route note 8, is required, including 30-minute fire-resisting construction”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Kitchen heat detector

LACORS national guide

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Emergency lighting

Council's own standard

“Emergency lighting is required if the means of escape does not have effective borrowed light.”
Fire Precautions in Dwellings (Breckland Council, Private Sector Housing), March 2023

Fire extinguishers

Council's own standard

“A multi-purpose extinguisher and a fire blanket are required in each kitchen.”
Fire Precautions in Dwellings (Breckland Council, Private Sector Housing), March 2023

Spotted something out of date? Tell us and we will check it.

Common questions

Do I need a fire risk assessment for a Breckland HMO licence?
The council's guidance talks about fire risk assessments, but it does not ask you to send one with your application. Fire safety law still says you need one.
Can I do my own HMO fire risk assessment in Breckland?
The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.
Which fire safety standard does Breckland use for HMOs?
Breckland publishes "Fire Precautions in Dwellings (Breckland Council, Private Sector Housing)" (March 2023). Like most councils, it builds on the national LACORS guide.
What fire alarm does a 3-storey shared house need in Breckland?
For a typical 3-storey shared house with 6 tenants, Breckland's rules work out at Grade D1, LD1. Your house may need something different depending on its layout, so check it properly with a fire risk assessment.

Check your Breckland HMO against the council's standard

Answer plain-English questions about your house and get a fire risk assessment report built on Breckland's rules. £45, no subscription.