Barking and Dagenham HMO fire safety requirements

Barking and Dagenham publishes its own HMO fire safety standard, "HMO Standards (London Borough of Barking and Dagenham)" (January 2023).

Is a fire risk assessment needed for the licence?

Yes, as a licence condition

You need a written fire risk assessment as a condition of the licence, and the council can ask to see it at any time.

Who can carry it out?

No rule on who writes it

The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.

Which standard applies?

HMO Standards (London Borough of Barking and Dagenham)

Published January 2023.

Read the council's document →

When did we last check?

14 October 2026

We re-check every council's documents each month and update this page when they change.

What Barking and Dagenham expects in 3 typical HMOs

Worked out from the council's own fire safety rules for three common kinds of HMO. Your house may need more or less depending on its layout, which is what a fire risk assessment is for.

2-storey shared house, 5 tenants

Fire alarm system
Grade D1, LD2, plus a linked smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended

3-storey shared house, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended

3-storey bedsits with cooking in rooms, 6 tenants

Fire alarm system
Grade A, LD2, plus a linked heat detector and a standalone smoke alarm in each letting
Fire doors on bedrooms
Required
Fire door on the kitchen
Required
Protected escape route
Required
Heat detector in the kitchen
Required
Emergency lighting
Not required
Fire blanket in the kitchen
Required
Fire extinguishers
Recommended
  • Grade D1 (mains alarms with a sealed backup battery)
  • Grade A (a panel system with call points)
  • LD2 (escape route plus rooms where fires are likely to start)

In the council's own words

The wording these requirements come from, quoted from the published documents.

Fire alarms

Council's own standard

“Provide a Fire Alarm System to include smoke detectors in every bedroom, throughout the escape route and in communal living rooms ... The system must comply with the current British Standard 5839 part 6: Grade DI, LD2 (or equivalent) ... interlinked with a control panel containing battery back-up. The system must comply with the current British Standard 5839 part 6: Grade A LD2 (or equivalent)”
HMO Standards (London Borough of Barking and Dagenham), January 2023

Fire doors

Council's own standard

“Two or more storey HMOs require self-closing fire doors that provide 30 minute fire and smoke protection (FD30S) on all bedrooms, kitchens and living rooms”
HMO Standards (London Borough of Barking and Dagenham), January 2023

Escape route

Council's own standard

“All HMOs shall be provided with an adequate protected means of escape from fire, together with other fire precautions”
HMO Standards (London Borough of Barking and Dagenham), January 2023

Kitchen heat detector

LACORS national guide

“additional interlinked heat alarm with integral battery back-up located in the kitchen”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Emergency lighting

LACORS national guide

“Emergency escape lighting required only if the route is long or complex or where there is no effective borrowed light ... Shared house HMO of five or six storeys (shared cooking facilities) Conventional lighting and emergency escape lighting”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Fire extinguishers

LACORS national guide

“a simple multi-purpose extinguisher is recommended on each floor in the common parts of HMOs and buildings containing flats.”
LACORS Housing - Fire Safety: guidance on fire safety provisions for certain types of existing housing, July 2008

Spotted something out of date? Tell us and we will check it.

Not in Barking and Dagenham?

Common questions

Do I need a fire risk assessment for a Barking and Dagenham HMO licence?
You need a written fire risk assessment as a condition of the licence, and the council can ask to see it at any time.
Can I do my own HMO fire risk assessment in Barking and Dagenham?
The council does not say who must carry out the fire risk assessment, so a landlord can do it themselves, as long as it is done properly.
Which fire safety standard does Barking and Dagenham use for HMOs?
Barking and Dagenham publishes "HMO Standards (London Borough of Barking and Dagenham)" (January 2023). Like most councils, it builds on the national LACORS guide.
What fire alarm does a 3-storey shared house need in Barking and Dagenham?
For a typical 3-storey shared house with 6 tenants, Barking and Dagenham's rules work out at Grade A, LD2, plus a linked smoke alarm in each letting. Your house may need something different depending on its layout, so check it properly with a fire risk assessment.

Check your Barking and Dagenham HMO against the council's standard

Answer plain-English questions about your house and get a fire risk assessment report built on Barking and Dagenham's rules. £45, no subscription.